MEADOW, TX —
OSHA Inspection: NEW HOME CO-OP GIN
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of NEW HOME CO-OP GIN in NEW HOME GIN, WEST FM 211, MEADOW, TX 79345 (NAICS 115111). OSHA activity number 307010108.
Where did this inspection happen?
- Establishment
- NEW HOME CO-OP GIN
- Site address
- NEW HOME GIN, WEST FM 211
- City
- MEADOW
- State
- TX
- ZIP
- 79345
- Mailing
- P.O. BOX 218, NEW HOME, TX 79383
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 115111
- SIC code (legacy)
- 0724
- Employees
- 40
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $875.00 · Current $525.00 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the condition(s) listed below: For the period of time up to and including 12/06/05, employees were not protected from fall hazards due to the following conditions: a) Areas over 15 feet high along the inside edge of the catwalks at the upper lint cleaners and stick machines did not have a railing in place. b) A railing was missing along the end of a platform over 15 feet high used to access the upper conveyor. Under the American National Standard A12.1 1973, paragraph 5.1 states "Every open-sided floor or platform 4 feet or more above adjacent floor or ground level shall be guarded by a railing (or the equivalent as specified in 7.3) on all open sides, except where excluded as specified in 1.2 and where there is entrance to a ramp, stairway or fixed ladder. Under the American National Standard A12.1 1973, paragraph 7.1 states "A guard railing shall consist of top rail, intermediate rail or equivalent protection, and posts, and shall have a vertical height within the range of 36 inches to 42 inches nominal from upper surface of top rail to floor, platform, runway, or ramp level. One feasible and acceptable abatement method would be to ensure all walking / working surfaces are installed / maintained in accordance with A12.1 of the American National Standards. "Pursuant to 29 CFR 1903.19(d), the employer must provide documentation that this violation has been abated within 10 calendar days after the abatement date."ent
Recent events (2)
- — I (S) $525.00
- — Z (S) $875.00
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $700.00 · Current $420.00 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the condition(s) listed below: For the period of time up to and including 12/06/05, employees were not protected from electrical hazards due to the following conditions: a)Two circuit breaker panel boxes had openings in them where circuit breakers had been removed, exposing employees to possible contact with the conductors inside. b)A cover was missing on a circuit breaker panel box. c)A Square D motor control breaker was mounted in a Cutler Hamner enclosure, which had the front cut with a torch to accommodate the motor control. This left openings along the edges which permitted the entry of dust. d)Several switch boxes in the motor control area had openings where switches had been moved or removed, which permitted the entry of dust. Under the National Electric Code (NEC 2005), Article 547.6 states "Switches, including pushbuttons, relays, and similar devices, receptacles, circuit breakers, controllers, and fuses shall be provided with enclosures as specified in 547.5(C)." Under the National Electric Code (NEC 2005), Article 547.5(C)(1) states "Equipment enclosures, boxes, conduit bodies, and fittings installed in areas of buildings where excessive dust may be present shall be designed to minimize the entrance of dust and shall have not openings (such as holes for attachment screws) through which dust could enter the enclosure. One feasible and acceptable abatement method would be to ensure all electrical equipment is installed / maintained in accordance with Article 547 of the National Electric Code. "Pursuant to 29 CFR 1903.19(d), the employer must provide documentation that this violation has been abated within 10 calendar days after the abatement date."ent
Recent events (2)
- — I (S) $420.00
- — Z (S) $700.00
More inspections in this industry (NAICS 115111)
SURRENCY, GA—2026-06-23 00:00:00
SOUTHEASTERN GIN, INC.
LEMOORE, CA—2025-12-16 00:00:00
WEST ISLAND COTTON GROWERS, INC.
SLATON, TX—2025-12-15 00:00:00
WESTEX COOPERATIVE GIN
SLATON, TX—2025-11-28 00:00:00
WESTEX COOPERATIVE GIN
LAMESA, TX—2025-11-12 00:00:00
UNITED GIN CORPORATION
More inspections in TX
WICHITA FALLS, TX—2026-07-16 00:00:00
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16 00:00:00
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15 00:00:00
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15 00:00:00
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15 00:00:00
NORTH STAR ENERGY SOLUTIONS LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 307010108.