RALEIGH, NC —
OSHA Inspection: OH DISTRIBUTORS, INC. DBA AUTO PARTS UNLIMITED
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of OH DISTRIBUTORS, INC. DBA AUTO PARTS UNLIMITED in 3201 WELLINGTON COURT, SUITE 112, RALEIGH, NC 27615 (NAICS 423120). OSHA activity number 307211748.
Where did this inspection happen?
- Establishment
- OH DISTRIBUTORS, INC. DBA AUTO PARTS UNLIMITED
- Site address
- 3201 WELLINGTON COURT, SUITE 112
- City
- RALEIGH
- State
- NC
- ZIP
- 27615
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423120
- SIC code (legacy)
- 5013
- Employees
- 18
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
12 citations on file for this inspection.
95012901
- Issued
- Abate by
- Penalty
- Initial $350.00 · Current $245.00 Reduced
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish to each of his employees conditions of employment and a place of employment free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to being struck by stored materials falling from the shelving:: a)site, warehouse, oil bay room - multiple metal storage racks, Reliable Upright, model #RU27420216 and Reliable Beam, model #RBN55144, 2 shelves high, with 1 shelf each set at approximately 79 inches and 158 inches above the concrete floor, where vertical legs/footings were not appropriately secured to the floor with 2 metal bolts, but had only one bolt attached and in place, and exhibited visible stress and bend/twist in the legs, along with visible stress and obvious bend/flex in the shelves causing 3 unsecured and unrestrained pallets weighing up to approximately 2300 - 2400 pounds each (total weight of approximately 6900 lbs) to lean and tilt in an unbalanced manner on beams rated at 4800 lbs total maximum weight. One feasible and acceptable abatement method, among others, to correct this hazard is to post the maximum load capacity allowed and test the loads to insure that the maximum load capacity is not exceeded; and/or replace the metal storage racks and/or necessary components with equipment which clearly exceeds the facilitys highest known and/or intended load. (Reference: Manufacturer, Wireway/Husky Corporation, 6146 Denver Industrial Park, Denver, NC 28037, Specification Sheet for Horizontal & Diagonal Bracing, Upright & Beam Selection, Capacities, Upright 42" x 18', Beam 5.5" x 144").
Recent events (2)
- — I (S) $245.00
- — Z (S) $350.00
1910.22 D01
- Issued
- Abate by
1910.22 B02
- Issued
- Abate by
- Penalty
- Initial $250.00 · Current $175.00 Reduced
Recent events (2)
- — I (S) $175.00
- — Z (S) $250.00
1910.176 A
- Issued
- Abate by
- Penalty
- Initial $250.00 · Current $175.00 Reduced
Recent events (2)
- — I (S) $175.00
- — Z (S) $250.00
1910.176 B
- Issued
- Abate by
1910.178 L01 II
- Issued
- Abate by
- Penalty
- Initial $350.00 · Current $245.00 Reduced
Recent events (2)
- — I (S) $245.00
- — Z (S) $350.00
1910.178 L06
- Issued
- Abate by
1910.305 G01 III
- Issued
- Abate by
- Penalty
- Initial $125.00 · Current $100.00 Reduced
Recent events (2)
- — I (S) $100.00
- — Z (S) $125.00
7F0102
- Issued
- Abate by
1910.303 G01 II
- Issued
- Abate by
1910.305 G02 III
- Issued
- Abate by
1910.157 C01
- Issued
- Abate by
More inspections in this industry (NAICS 423120)
ANN ARBOR, MI—2026-07-14 00:00:00
CRP INDUSTRIES
BALTIMORE, MD—2026-07-14 00:00:00
D & W CLUTCH & BRAKE, INC.
KENT, WA—2026-06-25 00:00:00
WA317991799 - PARKER HANNIFIN CORP
OMAHA, NE—2026-06-24 00:00:00
A.C. NELSEN ENTERPRISES INC.
POMPANO BEACH, FL—2026-06-15 00:00:00
PARTS AUTHORITY LLC
More inspections in NC
LENOIR, NC—2026-07-16 00:00:00
161563 - CSP INNOVATIONS NORTH CAROLINA, INC.
LAKE PARK, NC—2026-07-15 00:00:00
161557 - UNION ELECTRIC MEMBERSHIP CORPORATION
HIGH POINT, NC—2026-07-15 00:00:00
161554 - SE BOARD, INC
LAKE PARK, NC—2026-07-15 00:00:00
161553 - QUALITY ARBOR SERVICES INC.
KERNERSVILLE, NC—2026-07-15 00:00:00
161552 - EDC, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 307211748.