MACON, GA —
OSHA Inspection: LIN R. ROGERS ELECTRICAL CONTRACTORS, INC.
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of LIN R. ROGERS ELECTRICAL CONTRACTORS, INC. in 3030 AIRPORT EAST ROAD, MACON, GA 31216 (NAICS 238210). OSHA activity number 307835058.
Where did this inspection happen?
- Establishment
- LIN R. ROGERS ELECTRICAL CONTRACTORS, INC.
- Site address
- 3030 AIRPORT EAST ROAD
- City
- MACON
- State
- GA
- ZIP
- 31216
- Mailing
- 2050 MARCONI DR., STE 200, ALPHARETTA, GA 30005
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- SIC code (legacy)
- 1731
- Employees
- 31
- Ownership type
- A
Citations
7 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $7000.00
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to falling from, getting struck by or being crushed by a scissor as the employer did not comply with ANSI A92.6-1990: At the Kohl's Distribution Center construction project in Macon, Ga. on or about 10/13/04, (a)Employees operating the Marklift J19EP were not able to refer to the operating and maintenance manual as the employer did not keep or maintain the manual(s) required in section 4.16.1. (b)A preventive maintenance program had not been developed for the company owned Marklift J19EP. The Marklift J19EP had not been inspected and serviced by a qualified mechanic who has specific knowledge of the Marklift J19EP. The lift had plain view defects and structural defects at the time of the inspection. The employee operating the lift was catapulted out of the lift when the bracket, roller support and wear pad became separated from the lift. The manufacturer and ANSI A92.6 require a preventive maintenance program. (c)The employer had not caused a frequent inspection to be performed on the scissor lift. The inspections are to be performed every three months or 150 hours whichever comes first or prior to returning to service after being out of service for three months or more. Such an inspection would include a visual inspection of the structural components and other critical components such as fasteners, pins, shafts and locking devices; (d)The employer had not caused an annual inspection of the lift by a person qualified as a mechanic on the Marklift J19EP. Among other methods, feasible and acceptable abatement methods to correct this hazard are: (a)to obtain a copy of the manual from the manufacturer; (b)to develop and implement a preventative maintenance plan for all company owned lifts as specified by the manufacturer and ANSI A92.6-1990 section 6.3. (c)to cause frequent inspections to be performed by a person qualified as a mechanic on the specific make and model of the aerial platform. The inspection shall include all items specified by the manufacturer and ANSI A92.6-1990 section 6.5. Retain written records of frequent inspections for a minimum of three years. The record shall include the date of the inspection, deficiencies found, corrective action and identification of the person(s) performing the inspection and repairs. (d)to cause annual inspections to be performed by a person qualified as a mechanic on the aerial platform. Retain written records of annual inspections for aminimum of three years. The record shall include deficiencies found, corrective action and identification of the person(s) performing the inspection and repairs.
Recent events (2)
- — D (S)
- — Z (S) $7000.00
1926.50 B
- Issued
- Abate by
- Penalty
- Initial $2500.00
Recent events (2)
- — D (S)
- — Z (S) $2500.00
1926.50 C
- Issued
- Abate by
Recent events (2)
- — D (S)
- — Z (S)
1926.451 F03
- Issued
- Abate by
- Penalty
- Initial $7000.00
Recent events (2)
- — D (S)
- — Z (S) $7000.00
1926.451 G04 IV
- Issued
- Abate by
- Penalty
- Initial $2500.00
Recent events (2)
- — D (S)
- — Z (S) $2500.00
1926.454 B
- Issued
- Abate by
- Penalty
- Initial $2500.00
Recent events (2)
- — D (S)
- — Z (S) $2500.00
1926.21 B02
- Issued
- Abate by
- Penalty
- Initial $12500.00
Recent events (2)
- — D (R)
- — Z (R) $12500.00
More inspections at LIN R. ROGERS ELECTRICAL CONTRACTORS, INC.
HENDERSON, NV—2023-07-17 00:00:00
LIN R. ROGERS ELECTRICAL CONTRACTORS, INC.
VISALIA, CA—2022-08-19 00:00:00
LIN R. ROGERS ELECTRICAL CONTRACTORS, INC.
ARVIN, CA—2022-06-10 00:00:00
LIN R. ROGERS ELECTRICAL CONTRACTORS, INC.
SAN ANTONIO, TX—2022-04-05 00:00:00
LIN R. ROGERS ELECTRICAL CONTRACTORS, INC.
SAVANNAH, GA—2018-02-28 00:00:00
LIN R. ROGERS ELECTRICAL CONTRACTORS, INC.
View LIN R. ROGERS ELECTRICAL CONTRACTORS, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238210)
NEW YORK, NY—2026-07-17 00:00:00
VERGARA ELECTRICAL LLC
WASHINGTON, IL—2026-07-17 00:00:00
SUNRUN INSTALLATION SERVICES, INC.
KAHULUI, HI—2026-07-16 00:00:00
RISING SUN SOLAR ELECTRIC LLC
PARKVILLE, MD—2026-07-15 00:00:00
THE POWER SOURCE, INC.
SOUTH BARRINGTON, IL—2026-07-15 00:00:00
EDGE ELECTRICAL SYSTEMS, LLC
More inspections in GA
CHAMBLEE, GA—2026-07-16 00:00:00
U.S. DEPARTMENT OF TREASURY
LAWRENCEVILLE, GA—2026-07-16 00:00:00
REHRIG PACIFIC COMPANY
GREENSBORO, GA—2026-07-16 00:00:00
PURE BEAUTY FARMS, INC.
FOREST PARK, GA—2026-07-16 00:00:00
POLYNT COMPOSITES USA INC.
AUGUSTA, GA—2026-07-16 00:00:00
GF CASTING SOLUTIONS AUGUSTA, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 307835058.