GREEN BAY, WI —
OSHA Inspection: WILCOX STEEL
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of WILCOX STEEL in 1240 CONTRACT DRIVE, GREEN BAY, WI 54304 (NAICS 331221). OSHA activity number 309835312.
Where did this inspection happen?
- Establishment
- WILCOX STEEL
- Site address
- 1240 CONTRACT DRIVE
- City
- GREEN BAY
- State
- WI
- ZIP
- 54304
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331221
- SIC code (legacy)
- 3316
- Employees
- 25
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $2100.00 · Current $1050.00 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the potential of severe burns and injuries from a dust explosion: a.)On or about December 21, 2006, employees were exposed to a dust explosion that could have resulted from, or been exacerbated by the baghouse collection systems which were located inside the building area and were not equipped with explosion suppression or venting components. Feasible means of abatement include, but are not limited to: *Comply with NFPA 484: "Standard for Combustible Metals, Section 12: Requirements for Combustible Metals Not Covered in Chapter 5 through Chapter 11," which states "Explosion venting is required for all buildings or building areas where combustible metal powders or dusts are present, unless a hazard analysis has been performed that shows that explosion venting is not required." *Comply with NFPA 484: "Standard for Combustible Metals, Section 12: Requirements for Combustible Metals Not Covered in Chapter 5 through Chapter 11," which states that "Dry-type dust collectors shall be located outside of the buildings." Abatement Certification and Abatement Documentation required.
Recent events (2)
- — F (S) $1050.00
- — Z (S) $2100.00
More inspections in this industry (NAICS 331221)
DEARBORN, MI—2026-06-29 00:00:00
BWD TECHNOLOGIES LLC
BRIDGEPORT, CT—2026-06-22 00:00:00
FEROLETO STEEL COMPANY, INC.
OAK GROVE, MO—2026-06-01 00:00:00
AXIAL CONCEPTS LLC.
GRAND RAPIDS, MI—2026-06-01 00:00:00
DENNEN STEEL LLC
SAUK VILLAGE, IL—2026-05-27 00:00:00
TARGET METAL BLANKING INC.
More inspections in WI
WAUSAU, WI—2026-07-16 00:00:00
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15 00:00:00
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15 00:00:00
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15 00:00:00
TERONOMY BUILDERS, INC.
DELAVAN, WI—2026-07-15 00:00:00
A. GOMEZ CARPENTRY, INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 309835312.