Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WILCOX STEEL

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of WILCOX STEEL in 1240 CONTRACT DRIVE, GREEN BAY, WI 54304 (NAICS 331221). OSHA activity number 309835312.

Watch Wilcox Steel — free Get an email when a new federal OSHA severe-injury report for Wilcox Steel is published. One employer, no account, unsubscribe in one click.
Establishment
WILCOX STEEL
Site address
1240 CONTRACT DRIVE
City
GREEN BAY
State
WI
ZIP
54304
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331221
SIC code (legacy)
3316
Employees
25
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $1050.00 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the potential of severe burns and injuries from a dust
explosion:
a.)On or about December 21, 2006, employees were exposed to a dust
explosion that could
have resulted from, or been exacerbated by the baghouse collection systems
which were
located inside the building area and were not equipped with explosion
suppression or
venting components.
Feasible means of abatement include, but are not limited to:
*Comply with NFPA 484: "Standard for Combustible Metals, Section 12:
Requirements
for Combustible Metals Not Covered in Chapter 5 through Chapter 11," which
states
"Explosion venting is required for all buildings or building areas where
combustible
metal powders or dusts are present, unless a hazard analysis has been
performed that
shows that explosion venting is not required."
*Comply with NFPA 484: "Standard for Combustible Metals, Section 12:
Requirements
for Combustible Metals Not Covered in Chapter 5 through Chapter 11," which
states that
"Dry-type dust collectors shall be located outside of the buildings."
Abatement Certification and Abatement Documentation required.
Recent events (2)
  • — F (S) $1050.00
  • — Z (S) $2100.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 309835312.