FUQUAY VARINA, NC —
OSHA Inspection: ZECHARIAH HOUSE CONST. LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ZECHARIAH HOUSE CONST. LLC in 6600 ALIRIN LANE, LOT 17, FUQUAY VARINA, NC 27526 (NAICS 238130). OSHA activity number 310046156.
Where did this inspection happen?
- Establishment
- ZECHARIAH HOUSE CONST. LLC
- Site address
- 6600 ALIRIN LANE, LOT 17
- City
- FUQUAY VARINA
- State
- NC
- ZIP
- 27526
- Mailing
- 147 CHRISTINE DRIVE, GARNER, NC 27529
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- SIC code (legacy)
- 1751
- Employees
- 6
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
6 citations on file for this inspection.
95012901
- Issued
- Abate by
- Penalty
- Initial $350.00 · Current $350.00
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish to each of his employees conditions of employment and a place of employment free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to electrical hazards as referenced in the NEC, 305-6(b): a)6600 Alirin Lane, lot 17-a temporary power pole was observed to have a 240v ac outlet with an inoperable GFCI, into which a Rol-Air compressor was plugged into and being accessed by employees. A feasible means of abatement is to manually check the 120v and 240v outlets on the temporary power pole for a functioning GFCI before plugging any equipment into the T-pole. If the GFCI is not operable, then the employer should contact the general contractor immediately.
1926.403 B01
- Issued
- Abate by
- Penalty
- Initial $350.00 · Current $350.00
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $250.00 · Current $250.00
1926.503 A01
- Issued
- Abate by
1926.404 F06
- Issued
- Abate by
1926.405 G02 III
- Issued
- Abate by
More inspections in this industry (NAICS 238130)
FAIRHOPE, AL—2026-07-16 00:00:00
FRANCISCO ARES
WOODHAVEN, MI—2026-07-16 00:00:00
G.J. PERELLI CO., L.L.C.
PHILADELPHIA, PA—2026-07-16 00:00:00
URUS CONSTRUCTION CORPORATION
BERLIN, NJ—2026-07-16 00:00:00
URUS CONSTRUCTION CORPORATION
MERIDIAN, ID—2026-07-15 00:00:00
TRIPLE R CONSTRUCTION LLC
More inspections in NC
KERNERSVILLE, NC—2026-07-15 00:00:00
161552 - EDC, INC.
FRANKLINTON, NC—2026-07-15 00:00:00
161551 - LINDSAY PRECAST, LLC
RALEIGH, NC—2026-07-14 00:00:00
161550 - SUNRISE SENIOR LIVING MANAGEMENT, INC.
LAURINBURG, NC—2026-07-14 00:00:00
161549 - AMERICAN WOOD FIBERS, INC.
RURAL HALL, NC—2026-07-14 00:00:00
161546 - CAVERT WIRE COMPANY, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 310046156.