Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MCCARTER-MOORHOUSE CO., INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MCCARTER-MOORHOUSE CO., INC in 3775 EAGLE ROAD, EAGLE, ID 83616 (NAICS 236220). OSHA activity number 311576235.

Watch Mccarter-Moorhouse CO., INC — free Get an email when a new federal OSHA severe-injury report for Mccarter-Moorhouse CO., INC is published. One employer, no account, unsubscribe in one click.
Site address
3775 EAGLE ROAD
City
EAGLE
State
ID
ZIP
83616
Mailing
10754 EXECUTIVE DRIVE, BOISE, ID 83713
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
SIC code (legacy)
1542
Employees
3
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 02 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $600.00
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not
furnish employment and a place of employment which were free from
recognized hazards
that were likely to cause death or serious physical harm to the employees
in that employees
were exposed to struck by/caught between hazards from roof truss collapse
during
installation:
a)3775 North Eagle Road: On April 16, 2008, and times prior thereto,
approximately 11 to 14 trusses, with spans between 45 to 50 feet, were
installed without top cord diagonal bracing.
b)3775 North Eagle Road: On April 16, 2008, and times prior thereto, 45
to 50 foot span trusses were installed without sufficient lateral bracing.
Single rows of metal truss spacers, used as short member lateral
restraints,  were installed one per side, near the midpoint of the top
chords.  Lateral bracing was not installed near the eaves/bearers nor at
the peak.
NOTE: Feasible and acceptable methods of abatement to correct this hazard
would be to
follow either the manufacturer's recommendations on roof truss erection or
the BSCI - B1,
Summary Sheet - Guide for Handling, Installing and Bracing of Metal Plate
Connected Wood
Trusses, and BCSI - B2, Truss Installation & Temporary Restraint/Bracing,
issued by the
Wood Truss Council of America and Truss Plate Institute.
Recent events (2)
  • — I (S)
  • — Z (S) $600.00

5(a)(1)

Serious Gravity 02 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $600.00 · Current $600.00
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not
furnish employment and a place of employment which were free from
recognized hazards
that were likely to cause death or serious physical harm to the employees
in that employees
were exposed to struck by/caught between hazards from roof truss damage
and failure:
a)3775 North Eagle Road: On April 16, 2008, the employer used a single
pick point to hoist and install 50 foot roof trusses.
NOTE: Feasible and acceptable methods of abatement to correct this hazard
would be to
follow the manufacturer's recommendations on roof truss erection and the
2006 edition of
BSCI -B1 Summary Sheet - Guide for Handling, Installing, Restraining &
Bracing of
Trusses, issued by the Wood Truss Council of America and Truss Plate
Institute.  This
clearly states "single trusses between 30 feet and 60 feet use a spreader
bar one half to two
thirds of the truss length.  Attach truss to the spreader bar with lines
that slope inward or
"toe-in.  Lines that "toe-out" can cause the truss to buckle".
Recent events (2)
  • — I (S) $600.00
  • — Z (S) $600.00

CBH HOMES