CLAYTON, NC —
OSHA Inspection: JUAN VILLALOBOS DBA JV'S PLASTERING DRYWALL SYSTEM
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JUAN VILLALOBOS DBA JV'S PLASTERING DRYWALL SYSTEM in 9257 HWY 70 W, CLAYTON, NC 27520 (NAICS 238310). OSHA activity number 311626204.
Where did this inspection happen?
- Establishment
- JUAN VILLALOBOS DBA JV'S PLASTERING DRYWALL SYSTEM
- Site address
- 9257 HWY 70 W
- City
- CLAYTON
- State
- NC
- ZIP
- 27520
- Mailing
- 1004-D VILLAGE GREEN WAY, CARY, NC 27511
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- SIC code (legacy)
- 1742
- Employees
- 5
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
6 citations on file for this inspection.
95012901
- Issued
- Abate by
- Penalty
- Initial $500.00 · Current $325.00 Reduced
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish each of his employees conditions of employment and a place of employment free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to being struck by falling loads due to the disregard of the industry recognized standard in that items used to support the pulley are not load rated: a)site-employees were exposed to falling loads in that the cross pieces of scaffold, wire used to connect pulley to cross pieces, length of cross pieces over the edge of the end of the scaffold, an approximate seven foot span, and the 1/4" bent piece of rebar used as a hook, are not rated to lift a bucket of stucco, estimated at up to 100 pounds, are not rated for the task. One feasible means of abatement is to install and use a properly rated hoisting system.g
Recent events (2)
- — I (S) $325.00
- — Z (S) $500.00
1926.451 C01
- Issued
- Abate by
- Penalty
- Initial $500.00 · Current $325.00 Reduced
Recent events (2)
- — I (S) $325.00
- — Z (S) $500.00
1926.451 C02 I
- Issued
- Abate by
Recent events (2)
- — I (S)
- — Z (S)
1926.451 E01
- Issued
- Abate by
Recent events (2)
- — I (S)
- — Z (S)
1926.451 G04
- Issued
- Abate by
Recent events (2)
- — I (S)
- — Z (S)
1926.100 A
- Issued
- Abate by
- Penalty
- Initial $500.00 · Current $325.00 Reduced
Recent events (2)
- — I (S) $325.00
- — Z (S) $500.00
More inspections in this industry (NAICS 238310)
HENDERSON, NV—2026-07-16 00:00:00
ROADRUNNER DRYWALL CORPORATION
BANNOCKBURN, IL—2026-07-16 00:00:00
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
NAMPA, ID—2026-07-15 00:00:00
INTERIOR SYSTEMS, INC.
BRIDGEPORT, WV—2026-07-14 00:00:00
EASLEY & RIVERS, INC.
ELLETTSVILLE, IN—2026-07-13 00:00:00
ENVIRO HEAT, LLC
More inspections in NC
LENOIR, NC—2026-07-16 00:00:00
161563 - CSP INNOVATIONS NORTH CAROLINA, INC.
LAKE PARK, NC—2026-07-15 00:00:00
161557 - UNION ELECTRIC MEMBERSHIP CORPORATION
HIGH POINT, NC—2026-07-15 00:00:00
161554 - SE BOARD, INC
LAKE PARK, NC—2026-07-15 00:00:00
161553 - QUALITY ARBOR SERVICES INC.
KERNERSVILLE, NC—2026-07-15 00:00:00
161552 - EDC, INC.
Source