Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FOX STRUCTURES, INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FOX STRUCTURES, INC in N8997 CTY HWY M, ROSENDALE, WI 54974 (NAICS 236220). OSHA activity number 312554819.

Watch FOX Structures, INC — free Get an email when a new federal OSHA severe-injury report for FOX Structures, INC is published. One employer, no account, unsubscribe in one click.
Establishment
FOX STRUCTURES, INC
Site address
N8997 CTY HWY M
City
ROSENDALE
State
WI
ZIP
54974
Mailing
2201 EASTLINE ROAD PO BOX 528, KAUKAUNA, WI 54130
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
SIC code (legacy)
1541
Employees
25
Ownership type
A

19 citations on file for this inspection.

1926.761 B

Serious Gravity 10 1 instance
Issued
Abate by

5(a)(1)

Serious Gravity 10 1 instance 23 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1400.00 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to fall hazards from an elevated scissor lift platform:
a) On December 17, 2009, employees were using a Genie GS3268RT scissor
lift as a
means of access and egress to the roof.  This use required the employees
to climb the
rails of the lift to reach the roof surface, exposing the employees to
falls in excess of
fifteen (15) feet.
b) The access gate to the platform of the lift was not closed when the
platform was
elevated.  This condition, combined with snow on the platform, exposed
employees to
falls in excess of twelve (12) feet.
Among other methods, feasible and acceptable means to correct this hazard
are
to ensure the
Genie 3268RT scissor lift is operated according to the acceptable
requirements of the approved
American National Standards for Self-Propelled Elevating Work Platforms
ANSI/SIA A92.6-
2006, Section 7, Responsibilities of the User, as well as other acceptable
industry practices.  The
ANSI consensus standard requires the following:
7.3Inspection and Maintenance.  Users shall inspect and maintain the
aerial platform
as required to ensure proper operation.
7.3.3  Pre-start Inspection.  Before use each day or at the beginning of
each shift, the
aerial platform shall be given a visual inspection and functional test.
7.6  Operator training and retraining.  Whenever a user directs or
authorizes an
individual to operate an aerial platform the user shall ensure the person
has been: 1)
trained before being assigned to operate the aerial platform. 2)
Familiarized with the
aerial platform to be operated. 3) Made aware of the responsibilities of
operators as
outlined in section 8 of this standard. 4) Retrained, if necessary, based
on the user's
observation and evaluation of the operator.
7.6.1  Trainee records. A record of the trainee's aerial platform
instruction shall be
maintained by the user for at least 4 years.
7.7  Familiarization before use.  The user shall permit only properly
trained personnel
to operate an aerial platform.  The user shall ensure that before use the
operator is
familiar with the model of the aerial platform to be operated.
7.10  Operator Warnings and Instructions.  The user shall direct personnel
operating the
aerial platform to be in compliance with the provisions set forth in this
standard.  The
user shall monitor their performance and supervise their work to ensure
the operation of
the aerial platform is in conformance with the provisions set forth in
this
standard.
7.10.4  Guardrails shall be installed and positioned, and access gates
shall be closed.
7.10.9  Personnel shall maintain a firm footing on the platform floor
while working.
Climbing on the midrail or toprail is prohibited.  The use of planks,
ladders, or any other
devices on the platform for achieving additional height is prohibited.
7.10.26  Interlocks or other safety devices shall not be altered or
disabled.
Abatement Certification and Documentation Required
Recent events (2)
  • — I (S) $1400.00
  • — Z (S) $2000.00

1926.21 B02

Serious Gravity 10 1 instance 24 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1400.00 Reduced
Recent events (2)
  • — I (S) $1400.00
  • — Z (S) $2000.00

1910.178 L01 I

Serious Gravity 10 1 instance 24 exposed
Issued
Abate by

1926.102 A01

Other-than-serious Gravity 02 1 instance 23 exposed
Issued
Abate by
Penalty
Initial $800.00
Recent events (2)
  • — I (O)
  • — Z (S) $800.00

1926.403 B01

Other-than-serious Gravity 05 1 instance 23 exposed
Issued
Abate by
Penalty
Initial $1400.00
Recent events (2)
  • — I (O)
  • — Z (S) $1400.00

1926.404 B01 III

Deleted Serious Gravity 10 1 instance 23 exposed
Issued
Abate by
Recent events (2)
  • — I (S)
  • — Z (S)

1926.404 B01 IIIC

Serious Gravity 10 1 instance 23 exposed
Issued
Abate by

1926.404 F03 III

Deleted Serious Gravity 10 1 instance 23 exposed
Issued
Abate by
Recent events (2)
  • — I (S)
  • — Z (S)

1926.453 A02

Serious Gravity 10 1 instance 23 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1400.00 Reduced
Recent events (2)
  • — I (S) $1400.00
  • — Z (S) $2000.00

1926.453 B02 I

Serious Gravity 10 1 instance 23 exposed
Issued
Abate by

1926.453 B02 IV

Serious Gravity 10 1 instance 23 exposed
Issued
Abate by

1926.453 B02 V

Serious Gravity 10 1 instance 23 exposed
Issued
Abate by

1926.454 B

Serious Gravity 10 1 instance 24 exposed
Issued
Abate by

1926.1053 B16

Other-than-serious Gravity 03 1 instance 23 exposed
Issued
Abate by
Penalty
Initial $1000.00
Recent events (2)
  • — I (O)
  • — Z (S) $1000.00

1926.1060 A01 V

Deleted Other-than-serious Gravity 03 1 instance 23 exposed
Issued
Abate by
Recent events (2)
  • — I (O)
  • — Z (S)

1926.501 B10

Serious Gravity 10 1 instance 23 exposed
Issued
Abate by
Penalty
Initial $5600.00 · Current $1400.00 Reduced
Recent events (2)
  • — I (S) $1400.00
  • — Z (R) $5600.00

1926.503 A01

Deleted Serious Gravity 10 1 instance 23 exposed
Issued
Abate by
Recent events (2)
  • — I (S)
  • — Z (S)

1926.25 A

Other-than-serious Gravity 02 1 instance 23 exposed
Issued
Abate by
Penalty
Initial $800.00 · Current $550.00 Reduced
Recent events (2)
  • — I (O) $550.00
  • — Z (S) $800.00

View FOX STRUCTURES, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 312554819.