ROSENDALE, WI —
OSHA Inspection: FOX STRUCTURES, INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FOX STRUCTURES, INC in N8997 CTY HWY M, ROSENDALE, WI 54974 (NAICS 236220). OSHA activity number 312554819.
Where did this inspection happen?
- Establishment
- FOX STRUCTURES, INC
- Site address
- N8997 CTY HWY M
- City
- ROSENDALE
- State
- WI
- ZIP
- 54974
- Mailing
- 2201 EASTLINE ROAD PO BOX 528, KAUKAUNA, WI 54130
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- SIC code (legacy)
- 1541
- Employees
- 25
- Ownership type
- A
Citations
19 citations on file for this inspection.
1926.761 B
- Issued
- Abate by
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1400.00 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fall hazards from an elevated scissor lift platform: a) On December 17, 2009, employees were using a Genie GS3268RT scissor lift as a means of access and egress to the roof. This use required the employees to climb the rails of the lift to reach the roof surface, exposing the employees to falls in excess of fifteen (15) feet. b) The access gate to the platform of the lift was not closed when the platform was elevated. This condition, combined with snow on the platform, exposed employees to falls in excess of twelve (12) feet. Among other methods, feasible and acceptable means to correct this hazard are to ensure the Genie 3268RT scissor lift is operated according to the acceptable requirements of the approved American National Standards for Self-Propelled Elevating Work Platforms ANSI/SIA A92.6- 2006, Section 7, Responsibilities of the User, as well as other acceptable industry practices. The ANSI consensus standard requires the following: 7.3Inspection and Maintenance. Users shall inspect and maintain the aerial platform as required to ensure proper operation. 7.3.3 Pre-start Inspection. Before use each day or at the beginning of each shift, the aerial platform shall be given a visual inspection and functional test. 7.6 Operator training and retraining. Whenever a user directs or authorizes an individual to operate an aerial platform the user shall ensure the person has been: 1) trained before being assigned to operate the aerial platform. 2) Familiarized with the aerial platform to be operated. 3) Made aware of the responsibilities of operators as outlined in section 8 of this standard. 4) Retrained, if necessary, based on the user's observation and evaluation of the operator. 7.6.1 Trainee records. A record of the trainee's aerial platform instruction shall be maintained by the user for at least 4 years. 7.7 Familiarization before use. The user shall permit only properly trained personnel to operate an aerial platform. The user shall ensure that before use the operator is familiar with the model of the aerial platform to be operated. 7.10 Operator Warnings and Instructions. The user shall direct personnel operating the aerial platform to be in compliance with the provisions set forth in this standard. The user shall monitor their performance and supervise their work to ensure the operation of the aerial platform is in conformance with the provisions set forth in this standard. 7.10.4 Guardrails shall be installed and positioned, and access gates shall be closed. 7.10.9 Personnel shall maintain a firm footing on the platform floor while working. Climbing on the midrail or toprail is prohibited. The use of planks, ladders, or any other devices on the platform for achieving additional height is prohibited. 7.10.26 Interlocks or other safety devices shall not be altered or disabled. Abatement Certification and Documentation Required
Recent events (2)
- — I (S) $1400.00
- — Z (S) $2000.00
1926.21 B02
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1400.00 Reduced
Recent events (2)
- — I (S) $1400.00
- — Z (S) $2000.00
1910.178 L01 I
- Issued
- Abate by
1926.102 A01
- Issued
- Abate by
- Penalty
- Initial $800.00
Recent events (2)
- — I (O)
- — Z (S) $800.00
1926.403 B01
- Issued
- Abate by
- Penalty
- Initial $1400.00
Recent events (2)
- — I (O)
- — Z (S) $1400.00
1926.404 B01 III
- Issued
- Abate by
Recent events (2)
- — I (S)
- — Z (S)
1926.404 B01 IIIC
- Issued
- Abate by
1926.404 F03 III
- Issued
- Abate by
Recent events (2)
- — I (S)
- — Z (S)
1926.453 A02
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1400.00 Reduced
Recent events (2)
- — I (S) $1400.00
- — Z (S) $2000.00
1926.453 B02 I
- Issued
- Abate by
1926.453 B02 IV
- Issued
- Abate by
1926.453 B02 V
- Issued
- Abate by
1926.454 B
- Issued
- Abate by
1926.1053 B16
- Issued
- Abate by
- Penalty
- Initial $1000.00
Recent events (2)
- — I (O)
- — Z (S) $1000.00
1926.1060 A01 V
- Issued
- Abate by
Recent events (2)
- — I (O)
- — Z (S)
1926.501 B10
- Issued
- Abate by
- Penalty
- Initial $5600.00 · Current $1400.00 Reduced
Recent events (2)
- — I (S) $1400.00
- — Z (R) $5600.00
1926.503 A01
- Issued
- Abate by
Recent events (2)
- — I (S)
- — Z (S)
1926.25 A
- Issued
- Abate by
- Penalty
- Initial $800.00 · Current $550.00 Reduced
Recent events (2)
- — I (O) $550.00
- — Z (S) $800.00
More inspections at FOX STRUCTURES, INC
APPLETON, WI—2024-08-27 00:00:00
FOX STRUCTURES, INC.
GREENVILLE, WI—2023-08-03 00:00:00
FOX STRUCTURES, INC.
FREEDOM, WI—2014-06-11 00:00:00
FOX STRUCTURES, INC.
NEWTON, WI—2014-05-01 00:00:00
FOX STRUCTURES INC
KAUKAUNA, WI—2008-06-18 00:00:00
FOX STRUCTURES INC
View FOX STRUCTURES, INC's full OSHA safety record →
More inspections in this industry (NAICS 236220)
ROCHESTER, NH—2026-07-17 00:00:00
STAR CONSTRUCTION SVS INC
WHITESTOWN, IN—2026-07-17 00:00:00
CENTRAL WELDING INC
MOUNTAIN LAKES, NJ—2026-07-17 00:00:00
JOHN CARUSO BUILDERS LLC
FAIRFAX, VA—2026-07-17 00:00:00
RYCON CONSTRUCTION, INC.
SHAWNEE, KS—2026-07-16 00:00:00
BRATTON BROTHERS CONTRACTING INC
More inspections in WI
GREEN BAY, WI—2026-07-17 00:00:00
PTS CONTRACTORS, INC.
WAUSAU, WI—2026-07-16 00:00:00
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15 00:00:00
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15 00:00:00
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15 00:00:00
TERONOMY BUILDERS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 312554819.