Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: BEVERIDGE CONSTRUCTION COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BEVERIDGE CONSTRUCTION COMPANY in 7447 SPENCER HWY, PASADENA, TX 77505 (NAICS 238130). OSHA activity number 312928203.

Watch Beveridge Construction Company — free Get an email when a new federal OSHA severe-injury report for Beveridge Construction Company is published. One employer, no account, unsubscribe in one click.
Site address
7447 SPENCER HWY
City
PASADENA
State
TX
ZIP
77505
Mailing
26272 EAST HOLLY LN, SPLENDORA, TX 77372
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
SIC code (legacy)
1751
Employees
10
Ownership type
A
Industry flags
Construction safety.

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4620.00 · Current $4620.00
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish
employment and a place of employment which were free from recognized
hazards that were
causing or likely to cause death or serious physical harm to employees in
that employees were
exposed to fall and struck by hazards due to truss collapse:
Employees were exposed to fall and struck-by hazards on June 15, 2011 when
several wood
trusses collapsed under the load imposed by stacked plywood being set on
unbraced trushes,
resulting in an employee falling approximately 13.9 feet.
Among others, methods to correct the hazards include, but are not limited
to:
a)Installation of temporary lateral and diagonal bracing at the top and
bottom of installed
trusses as outlined in the Building Component Safety Information (BCSI)
Guide For
Handling, Installing, Restraining and Bracing of Trusses, published and
jointly produced
by the Structural Building Components Association, Wood Truss Council of
America
and
the Truss Plate Institute.
b)Ensuring that the maximum loading of trusses under construction was not
exceeded, in
as outlined in the Building Component Safety Information (BCSI) Guide For
Handling,
Installing, Restraining and Bracing of Trusses, published and jointly
produced by the
Structural Building Components Association, Wood Truss Council of America
and the
Truss Plate Institute.

1926.21 B02

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4620.00 · Current $4620.00

RNWBL

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 312928203.