NEKOOSA, WI —
OSHA Inspection: ERCO WORLDWIDE (USA), INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ERCO WORLDWIDE (USA), INC. in 101 HWY 73 SOUTH, NEKOOSA, WI 54457 (NAICS 325181). OSHA activity number 313138349.
Where did this inspection happen?
- Establishment
- ERCO WORLDWIDE (USA), INC.
- Site address
- 101 HWY 73 SOUTH
- City
- NEKOOSA
- State
- WI
- ZIP
- 54457
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325181
- SIC code (legacy)
- 2812
- Employees
- 96
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
6 citations on file for this inspection.
1910.119 D02 ID
- Issued
- Abate by
- Penalty
- Initial $3750.00
General-duty citation text
29 CFR 1910.119(d)(2)(i)(D): Process safety information pertaining to the technology of the process did not include the safe upper and lower limits for such items as temperatures, pressures, flows or compositions: The employer did not include the safe upper and lower limits for pressure, temperature, capacity, flow, composition, pH, etc. in the process safety information for the covered processes. a) Chlorine 334 Pig safe upper and lower limits for NCl3 concentration. b) Chlorine Liquefaction Main York South safe upper and lower limits for percent composition of hydrogen in tail gas to the HCl plant. c) Chlorine Liquefaction Main York North safe upper and lower limits for percent composition of hydrogen in tail gas to HCl plant. ABATEMENT CERTIFICATION REQUIRED PER 29 CFR 1903.19(c)ION
Recent events (2)
- — I (S)
- — Z (S) $3750.00
1910.119 F01 ID
- Issued
- Abate by
- Penalty
- Initial $3750.00
General-duty citation text
29 CFR 1910.119(f)(1)(i)(D): The employer's written operating procedures covering the steps for each operating phase did not address emergency shutdown including the conditions under which emergency shutdown is required, and the assignment of shutdown responsibility to qualified operators to ensure that emergency shutdown in a safe and timely manner: The employer's written operating procedures did not address the conditions for which emergency shutdown is required or the assignment of shutdown responsibilities for the covered processes. a) Operating pressure for emergency shutdown for the 334 Pig. b) Percent volume Cl2 in tail gas to HCL plant from secondary chlorine condenser to the North York Compressor. c) Percent volume Cl2 in tail gas to HCL plant from secondary chlorine condenser to the South York Compressor. ABATEMENT CERTIFICATION REQUIRED PER 29 CFR 1903.19(c)ION
Recent events (2)
- — I (S)
- — Z (S) $3750.00
1910.119 F01 IIB
- Issued
- Abate by
General-duty citation text
29 CFR 1910.119(f)(1)(ii)(B): The employer's written operating procedures covering the operating limits did not address the steps required to correct or avoid deviation beyond such operating limits: The employer's written operating procedures did not address the steps required to correct or avoid deviation for the upper and/or lower operating limits for the HCL Synthesis - Hydrogen Feed Stream's Hydrogen to Oxygen ratio (%). ABATEMENT CERTIFICATION REQUIRED PER 29 CFR 1903.19(c)
Recent events (2)
- — I (S)
- — Z (S)
1910.119 D02 ID
- Issued
- Abate by
- Penalty
- Current $3750.00
Recent events (3)
- — Q $3750.00
- — I (S) $3750.00
- — Z (S) $3750.00
1910.119 F01 ID
- Issued
- Abate by
Recent events (3)
- — Q $3750.00
- — I (S)
- — Z (S) $3750.00
1910.119 F01 IIB
- Issued
- Abate by
General-duty citation text
29 CFR 1910.119(f)(1)(ii)(B): The employer's written operating procedures covering the operating limits did not address the steps required to correct or avoid deviation beyond such operating limits: The employer's written operating procedures did not address the steps required to correct or avoid deviation for the upper and/or lower operating limits for the HCL Synthesis - Hydrogen Feed Stream's Hydrogen to Oxygen ratio (%). ABATEMENT CERTIFICATION REQUIRED PER 29 CFR 1903.19(c)
Recent events (2)
- — I (S)
- — Z (S)
More inspections at ERCO WORLDWIDE (USA), INC.
NEKOOSA, WI—2012-02-15 00:00:00
ERCO WORLDWIDE (USA), INC.
NEKOOSA, WI—2005-11-09 00:00:00
ERCO WORLDWIDE (USA), INC.
View ERCO WORLDWIDE (USA), INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325181)
LONGVIEW, WA—2025-05-13
WA317986042 - WESTLAKE MANAGEMENT SERVICES INC
LONGVIEW, WA—2024-10-17 00:00:00
WA317982755 - WESTLAKE MANAGEMENT SERVICES INC
EAST SAINT LOUIS, IL—2019-03-18 00:00:00
STELLAR MANUFACTURING COMPANY
LONGVIEW, WA—2018-09-21 00:00:00
WA317951149 - EAGLE US 2 LLC
KEARNY, NJ—2017-11-29 00:00:00
KUEHNE CHEMICAL CO., INC.
More inspections in WI
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15
TERONOMY BUILDERS, INC.
DELAVAN, WI—2026-07-15
A. GOMEZ CARPENTRY, INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 313138349.