OAK CREEK, WI —
OSHA Inspection: NUCOR COLD FINISH WISCONSIN, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of NUCOR COLD FINISH WISCONSIN, INC. in 7200 S. 6TH ST., OAK CREEK, WI 53154 (NAICS 331221). OSHA activity number 313524316.
Where did this inspection happen?
- Establishment
- NUCOR COLD FINISH WISCONSIN, INC.
- Site address
- 7200 S. 6TH ST.
- City
- OAK CREEK
- State
- WI
- ZIP
- 53154
- Mailing
- PO BOX 48, OAK CREEK, WI 53154
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331221
- SIC code (legacy)
- 3316
- Employees
- 62
- Ownership type
- A
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $2975.00 · Current $2975.00
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to metal dust explosion, deflagration or other fire hazards: (a)The Sunspan dust collector associated with Wheelabrator cleaning station number 2 was located inside the building, had no deflagration vents and recycled air back into the building. (b)The Wheelabrator dust collector associated with Wheelabrator cleaning stations number 3 and 4 was located inside the building, had no deflagration vents and recycled air back into the building. Feasible abatement methods include complying with NFPA 484 Standard for Combustible Metals, such as but not limited to: (1) moving the Sunspan and Wheelabrator dust collectors to a safe outdoor location; (2) installing deflagration vents on the Sunspan and Wheelabrator dust collectors; (3) installing deflagration isolation systems such as abort gates on ductwork; and (4) discharging air exhausted from the Sunspan and Wheelabrator dust collectors to a safe outdoor location. Certification, and documentation/evidence of abatement is required. Certification of abatement is required by 29 CFR Part 1903 and is to be submitted within ten (10) calendar days after the abatement date.ment
Recent events (2)
- — F (S) $2975.00
- — Z (S) $2975.00
1910.36 G02
- Issued
- Abate by
- Penalty
- Initial $1083.00 · Current $1083.00
Recent events (2)
- — F (S) $1083.00
- — Z (S) $1083.00
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $2125.00 · Current $2125.00
Recent events (2)
- — F (S) $2125.00
- — Z (S) $2125.00
More inspections in this industry (NAICS 331221)
BIRMINGHAM, AL—2026-07-14 00:00:00
THE MILL STEEL CORPORATION
DEARBORN, MI—2026-06-29 00:00:00
BWD TECHNOLOGIES LLC
BRIDGEPORT, CT—2026-06-22 00:00:00
FEROLETO STEEL COMPANY, INC.
OAK GROVE, MO—2026-06-01 00:00:00
AXIAL CONCEPTS LLC.
GRAND RAPIDS, MI—2026-06-01 00:00:00
DENNEN STEEL LLC
More inspections in WI
GREEN BAY, WI—2026-07-17 00:00:00
PTS CONTRACTORS, INC.
WAUSAU, WI—2026-07-16 00:00:00
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15 00:00:00
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15 00:00:00
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15 00:00:00
TERONOMY BUILDERS, INC.
Source