OSHA Inspection: NUCOR COLD FINISH WISCONSIN, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of NUCOR COLD FINISH WISCONSIN, INC. in 7200 S. 6TH ST., OAK CREEK, WI 53154 (NAICS 331221). OSHA activity number 313524316.

Watch Nucor Cold Finish Wisconsin, INC. — free Get an email when a new federal OSHA severe-injury report for Nucor Cold Finish Wisconsin, INC. is published. One employer, no account, unsubscribe in one click.
Site address
7200 S. 6TH ST.
City
OAK CREEK
State
WI
ZIP
53154
Mailing
PO BOX 48, OAK CREEK, WI 53154
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331221
SIC code (legacy)
3316
Employees
62
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 05 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $2975.00 · Current $2975.00
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish
employment and a place of employment which were free from recognized
hazards that were
causing or likely to cause death or serious physical harm to employees in
that employees were
exposed to metal dust explosion, deflagration or other fire hazards:
(a)The Sunspan dust collector associated with Wheelabrator cleaning
station number
2 was located inside the building, had no deflagration vents and recycled
air back
into the building.
(b)The Wheelabrator dust collector associated with Wheelabrator cleaning
stations
number 3 and 4 was located inside the building, had no deflagration vents
and
recycled air back into the building.
Feasible abatement methods include complying with NFPA 484 Standard for
Combustible
Metals, such as but not limited to: (1) moving the Sunspan and
Wheelabrator
dust collectors to
a safe outdoor location; (2) installing deflagration vents on the Sunspan
and Wheelabrator dust
collectors; (3) installing deflagration isolation systems such as abort
gates on ductwork; and (4)
discharging air exhausted from the Sunspan and Wheelabrator dust
collectors to a safe outdoor
location.
Certification, and documentation/evidence of abatement is required.
Certification of abatement is required by 29 CFR Part 1903 and is to be
submitted within ten (10)
calendar days after the abatement date.ment
Recent events (2)
  • — F (S) $2975.00
  • — Z (S) $2975.00

1910.36 G02

Deleted Serious Gravity 01 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $1083.00 · Current $1083.00
Recent events (2)
  • — F (S) $1083.00
  • — Z (S) $1083.00

1910.212 A01

Deleted Serious Gravity 03 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $2125.00 · Current $2125.00
Recent events (2)
  • — F (S) $2125.00
  • — Z (S) $2125.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 313524316.