PARKS, NE —
OSHA Inspection: DL CATTLE TRADING LLC DBA DL CATTLE LLC & DL FARMS
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of DL CATTLE TRADING LLC DBA DL CATTLE LLC & DL FARMS in 70952 AVENUE 330A, PARKS, NE 69041 (NAICS 112112). OSHA activity number 314059684.
Where did this inspection happen?
- Establishment
- DL CATTLE TRADING LLC DBA DL CATTLE LLC & DL FARMS
- Site address
- 70952 AVENUE 330A
- City
- PARKS
- State
- NE
- ZIP
- 69041
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 112112
- SIC code (legacy)
- 0211
- Employees
- 15
- Ownership type
- A
Citations
13 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $4000.00
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to live electrical components. The employer failed to ensure that the employees were protected from contact with live electrical components in the maintenance building operating at voltages ranging from 120V to 240V. The live components include but are not limited to extension cords used to power portable equipment that were damaged and repaired with electrical tape; extension cord was showing signs of strain relief in that the insulated (Sheath) portion of the cord was pulled away from the plug creating a potential for direct strain on the electrical contacts. A power cord was run under and through a door opening. This power cord was carrying 240V to a Wire Feed Welder located outside the maintenance facility. The door was made of steel with a steel threshold. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THIS HAZARD IS: 1.Repairs to extension cords shall be done in accordance with Article 110-14(b) and retain the insulation, outer sheath properties, and usage characteristics of the cord. Repairs shall only be done on No. 14 and larger conductors. Article 400-9 (National Fire Protection Association (NFPA) 70-National Electrical Code (NEC) 2011) 2.Do not run flexible cords through doorways or similar openings. Article 400-8 (NFPA 70-NEC 2011) 3.Develop and implement written procedures requiring that prompt corrective action is taken any time that an electrical issue is identified. 4.Develop and implement a disciplinary action program and procedures to ensure that employees report damage as it occurs and take action to ensure that the extension cords and flexible power cords are not abused/neglected. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photograph or videos which you believe will be helpful. The abatement certification sheet is enclosed with citation.
Recent events (2)
- — F (S)
- — Z (S) $4000.00
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $5600.00 · Current $5600.00
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to chemical hazards due to lack of eyewash facilities when working with corrosives. a)On the East wall of the maintenance building, employees are exposed to a hazard of receiving injurious corrosive liquids into the eyes, when performing maintenance on lead-acid batteries and recharging the same for purposes of energizing cattle fencing. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THIS HAZARD IS: a)Install an eye wash station that is located as close to the hazard as possible ANSI Z 358.1 (2004) b)Install an eye wash station that is not separated by a partition from the hazardous work area. ANSI Z 358.1 (2004) c)Install an eye wash station on an unobstructed path between the workstation and the hazard. (Workers should not have to pass through doorways or weave through machinery or other obstacles to reach them.) ANSI Z 358.1 (2004) d)Install an eye wash station that is located where workers can easily see them - preferably in a normal traffic pattern. ANSI Z 358.1 (2004) Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photograph or videos which you believe will be helpful. The abatement certification sheet is enclosed with citation.
Recent events (2)
- — F (S) $5600.00
- — Z (S) $5600.00
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $5600.00 · Current $5600.00
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fire and explosion hazards. a) Outside the North West corner of the middle building the employees at the establishment are exposed to hazards of fire and explosion associated with gas and diesel tanks as the tanks were not spaced at least 3 feet apart, tanks were not protected from physical damage, alarm system was not in place in the event of fuel leaks, fuel tanks were not supported in accordance with NFPA 30 (2008) and the vents were not of sufficient height. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THIS HAZARD IS: i)Provide for spacing 3 feet or greater for all fuel tanks. NFPA 30 (2008), 22.4.2.1. ii)Every Tank that contains a Class I, Class II or Class IIA liquid shall be provided with means to prevent an accidental release of liquid as required by NFPA 30 (2008) 22.11. iii)Supports for tanks shall be of concrete (protect against corrosion), masonry, or protected steel. Steel Support structures shall be protected by materials having a fire resistance rating of not less than 2 hours unless the support is a saddle no more than 12 inches high at the lowest point. NFPA 30 (2008), 22.5.1 iv)Provide a normal vent to prevent over-pressure or vacuum from damaging the tank when it is being filled or product is being withdrawn. The vent for a tank for Class I liquids must be normally closed, and it must terminate no less than 12 feet above ground level. NFPA 30 (2008), Chapter 27 v)Install protection for tanks located where they are subject to vehicular impact. NFPA 30 (2008), 22.15 vi)Establish an emergency action plan Planning for effective fire control measures shall be coordinated with local emergency response agencies. NFPA 30 (2008), 21.6.5 b) At the maintenance building employees were exposed to fire and explosion hazards as the oxygen cylinders were located next to acetylene cylinder and the cylinders were not secured. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THIS HAZARD IS: i)Separation of oxygen and fuel gas cylinders. CGA Pamphlet P1-1965 ii)Securing of cylinders in location were they can not be damaged or knocked over. CGA Pamphlet P-1-1965 Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photograph or videos which you believe will be helpful. The abatement certification sheet is enclosed with citation.
Recent events (3)
- — P (S) $5600.00
- — F (S) $5600.00
- — Z (S) $5600.00
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $4000.00 · Current $4000.00
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were to a fall hazard. a) South East corner of Middle Building employees were exposed to fall hazard where standard guard rail and stair rail were not installed on the stairs leading up to the landing of the mezzanine and on the East side of the mezzanine. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THIS HAZARD IS: i)Install a standard guard rail along the East side of the Mezzanine. (ANSI) A1264.1 - 2007. ii)Install a Standard Hand Rail on both sides of the Stair leading up to the Mezzanine. A1264.1 - 2007. Abatement certification is required for this violation. The abatement certification sheet is enclosed with citation.
Recent events (2)
- — F (S) $4000.00
- — Z (S) $4000.00
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $4800.00 · Current $4800.00
Recent events (2)
- — F (S) $4800.00
- — Z (S) $4800.00
1910.1200 H03 III
- Issued
- Abate by
Recent events (3)
- — P (S)
- — F (S)
- — Z (S)
1910.1200 F05 II
- Issued
- Abate by
- Penalty
- Initial $2400.00
Recent events (2)
- — F (S)
- — Z (S) $2400.00
1928.57 A06
- Issued
- Abate by
- Penalty
- Initial $5600.00
Recent events (3)
- — P (O)
- — F (O)
- — Z (S) $5600.00
1928.57 C02 I
- Issued
- Abate by
- Penalty
- Initial $4000.00 · Current $4000.00
Recent events (2)
- — F (S) $4000.00
- — Z (S) $4000.00
1928.57 C04 I
- Issued
- Abate by
- Penalty
- Initial $5600.00
Recent events (2)
- — F (S)
- — Z (S) $5600.00
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $70000.00 · Current $18000.00 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that the employer is failing to protect employees from asphyxiation hazards at the facility. a) The employees are exposed to hazards of asphyxiation, heat, and/or entrapment when frequently entering grain bins in order to break up clumps of corn. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THIS HAZARD IS: i) The employer shall implement safeguards such as rescue and retrieval equipment as outlined in Section 14 and 12.2 respectively, of ANSI Z117.1 - 2009 ii)The employer shall identify and evaluate the establishment for hazard identification as outlined in Section 3 of American National Standard Institute (ANSI) Z117.1 - 2009. iii)The employer shall implement an entry permit system as outlined in Section 5 of ANSI Z117.1 - 2009. iv)The employer shall conduct atmospheric testing as outlined in section 6 of ANSI Z117.1 - 2009 v)The employer shall follow all attendant requirements as outlined in Section 7 of ANSI Z117.1 - 2009 Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photograph or videos which you believe will be helpful. The abatement certification sheet is enclosed with citation.
Recent events (2)
- — F (R) $18000.00
- — Z (W) $70000.00
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $70000.00 · Current $18000.00 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that the employer is failing to protect employees from engulfment hazrds when employees enter and work in grain storage bins containing flowing grain. The employees are exposed to engulfment hazards when they enter the grain bins from the top while the auger is running below. The auger is not disconnected or locked out when the employees are inside the grain bins on the flowing grain. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THIS HAZARD IS: i) The employer shall institute and follow machine guarding and lockout procedures as identified in ANSI Z244.1 - 2003. ii) The employer shall prohibit employees from entering grain storage structures to walk on the grain to make it flow as identified in ANSI Z117.1 - 2009. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photograph or videos which you believe will be helpful. The abatement certification sheet is enclosed with citation.
Recent events (2)
- — F (R) $18000.00
- — Z (W) $70000.00
1904.39 A
- Issued
- Abate by
- Penalty
- Initial $4000.00 · Current $4000.00
Recent events (2)
- — F (O) $4000.00
- — Z (O) $4000.00
More inspections in this industry (NAICS 112112)
GRAND VIEW, ID—2026-07-11 00:00:00
J. R. SIMPLOT COMPANY
ORLAND, CA—2026-07-01 00:00:00
MISSION LIVESTOCK
QUINCY, WA—2026-04-22 00:00:00
WA317990878 - BEEF NORTHWEST FEEDERS LLC
WARDEN, WA—2026-01-26 00:00:00
WA317989538 - BEEF NORTHWEST FEEDERS LLC
INDIANOLA, NE—2026-01-22 00:00:00
NA TIMMERMAN, INC
More inspections in NE
CRETE, NE—2026-07-15 00:00:00
SMITHFIELD FOODS
OMAHA, NE—2026-07-14 00:00:00
LACO ENTERPRISES, LLC
OMAHA, NE—2026-07-10 00:00:00
WINGSTOP
LINCOLN, NE—2026-07-01 00:00:00
SMITHFIELD PACKAGED MEATS CORP.
LINCOLN, NE—2026-06-30 00:00:00
PATRIOT PLUMBING, HEATING & AC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314059684.