Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MAINE DRILLING & BLASTING, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MAINE DRILLING & BLASTING, INC. in HALF TOWNSHIP ROAD, LINCOLN, ME 04457 (NAICS 238910). OSHA activity number 314960477.

Watch Maine Drilling & Blasting, INC. — free Get an email when a new federal OSHA severe-injury report for Maine Drilling & Blasting, INC. is published. One employer, no account, unsubscribe in one click.
Site address
HALF TOWNSHIP ROAD
City
LINCOLN
State
ME
ZIP
04457
Mailing
P.O. BOX 1140, GARDINER, ME 04345
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
SIC code (legacy)
1629
Employees
14
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 6 instances 15 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $1000.00 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to fractures, lacerations, and internal injuries from
rotating and/or moving drills
and drill components:
In the following instances energy control procedures were not instituted
to protect employees
from the hazards of rotating and moving drills and drill components:
a)Rollins Wind Farm, Pad 19 - On or about 10/28/2010, an employee was
seriously
injured due to entanglement with a rotating drill.  The employee was
wearing
loose clothing and administrative controls had not been instituted.
b)Rollins Wind Farm, Pad 19 - On or about 10/28/2010, an employee was
seriously
injured due to entanglement with a rotating drill.  During a drill bit
change,
the
drill bit was positioned in close proximity to the drill operating
controls and
energy control procedures had not been instituted.
c) Rollins Wind Farm, Pad 19 - On or about 10/28/2010, an employee was
seriously
injured due to entanglement with a rotating drill.  The drill rotation
control was
initiated while the employee was in close proximity to the drill and
return to
service procedures had not been instituted.
d)Rollins Wind Farm, Pad 19 - On or about 10/28/2010, during a drill bit
change
the bit was threaded by hand while the employee activated the rotation
control
and equipment isolation had not been achieved.
e)Rollins Wind Farm, Pad 19 and Access Road - On or about 10/28/2010 and
11/3/2010, during drill bit changes the lockout and/or tagout devices were
not
affixed to the drill's energy isolation device in a manner that would
ensure that
the drill remained in a safe or off position.
f)Rollins Wind Farm, Pad 19 and Access Road - On or about 10/28/2010 and
11/3/2010, during drill bit changes the elevated drill attachment
(containing the
rod, feed, hose drum and drill apparatus) was not grounded, blocked, and/or
isolated.
Among other methods, one feasible and acceptable means of abatement would
be to institute
procedures for the control of hazardous energy as prescribed in ANSI/ASSE
Z244.1-2003
Control of Hazardous Energy Lockout/Tagout and Alternative Methods.ive
Recent events (2)
  • — F (S) $1000.00
  • — Z (S) $7000.00

1926.50 B

Serious Gravity 10 1 instance 14 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $7000.00
Recent events (2)
  • — F (S) $7000.00
  • — Z (S) $7000.00

View MAINE DRILLING & BLASTING, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314960477.