FESTUS, MO —
OSHA Inspection: DPC ENTERPRISES
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of DPC ENTERPRISES in 1785 SOUTH HIGHWAY 61, FESTUS, MO 63028 (NAICS 325998). OSHA activity number 315550376.
Where did this inspection happen?
- Establishment
- DPC ENTERPRISES
- Site address
- 1785 SOUTH HIGHWAY 61
- City
- FESTUS
- State
- MO
- ZIP
- 63028
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325998
- SIC code (legacy)
- 2899
- Employees
- 12
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C02 II
- Issued
- Abate by
- Penalty
- Initial $2295.00 · Current $2295.00
General-duty citation text
29 CFR 1910.147(c)(2)(ii): When an energy isolating device was capable of being locked out, the employer's energy control program under paragraph (c)(1) of this section did not utilize lockout: a. A wheel valve, regulating flow from a bleach tank, was not locked out (a tag was used instead). (Note: 1910.147(c)(3)(ii) requires an employer to demonstrate equally effective protection when tagout is used, including removing of a valve handle, which was not done in this instance). Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (O) $2295.00
- — Z (S) $2295.00
1910.119 D03 IB
- Issued
- Abate by
General-duty citation text
29 CFR 1910.119(d)(3)(i)(B): Process safety information pertaining to the equipment in the process did not include the piping and instrument diagrams (P&ID'S): a. Two instances existed of manual valves identified as actuated valves on the P&ID's (manifold). b. A manual valve to reactor #3 was not shown on the P&ID.
More inspections at DPC ENTERPRISES
EATONTON, GA—2007-01-31 00:00:00
DPC ENTERPRISES
FESTUS, MO—2002-08-14 00:00:00
DPC ENTERPRISES
EATONTON, GA—1994-06-29 00:00:00
DPC ENTERPRISES
View DPC ENTERPRISES's full OSHA safety record →
More inspections in this industry (NAICS 325998)
WILLOWS, CA—2026-07-15 00:00:00
HYERA INC
SAN ANTONIO, TX—2026-07-15 00:00:00
BLUE LINE CORPORATION
CHARLOTTE, TX—2026-07-07 00:00:00
CLEMENTS FLUIDS
KINDRED, ND—2026-06-29 00:00:00
ICE CRYSTAL ENGINEERING
WAYNESVILLE, NC—2026-06-23 00:00:00
161409 - PREMIER MAGNESIA, LLC
More inspections in MO
CLINTON, MO—2026-07-14 00:00:00
TORCHYLO BUILDERS, LLC.
BLUE SPRINGS, MO—2026-07-13 00:00:00
JORGE MERIDA
KANSAS CITY, MO—2026-07-09 00:00:00
NIAGARA BOTTLING
MONETT, MO—2026-07-09 00:00:00
MONETT METALS INC.
KANSAS CITY, MO—2026-07-08 00:00:00
NGC CONSTRUCTION LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 315550376.