Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: DPC ENTERPRISES

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of DPC ENTERPRISES in 1785 SOUTH HIGHWAY 61, FESTUS, MO 63028 (NAICS 325998). OSHA activity number 315550376.

Watch DPC Enterprises — free Get an email when a new federal OSHA severe-injury report for DPC Enterprises is published. One employer, no account, unsubscribe in one click.
Establishment
DPC ENTERPRISES
Site address
1785 SOUTH HIGHWAY 61
City
FESTUS
State
MO
ZIP
63028
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325998
SIC code (legacy)
2899
Employees
12
Ownership type
A

2 citations on file for this inspection.

1910.147 C02 II

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2295.00 · Current $2295.00
29 CFR 1910.147(c)(2)(ii): When an energy isolating device was capable of
being locked out,
the employer's energy control program under paragraph (c)(1) of this
section did not utilize
lockout:
a. A wheel valve, regulating flow from a bleach tank, was not locked out
(a tag was used
instead).  (Note: 1910.147(c)(3)(ii) requires an employer to demonstrate
equally effective
protection when tagout is used, including removing of a valve handle,
which was not
done in this instance).
Abatement certification and abatement documentation is required for this
violation.  The
documentation should include written verification of abatement, applicable
measurements
or monitoring results, and photographs or videos which you believe will be
helpful.  The
abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • — I (O) $2295.00
  • — Z (S) $2295.00

1910.119 D03 IB

Other-than-serious Gravity 01 2 instances 2 exposed
Issued
Abate by
29 CFR 1910.119(d)(3)(i)(B):  Process safety information pertaining to the
equipment in the
process did not include the piping and instrument diagrams (P&ID'S):
a. Two instances existed of manual valves identified as actuated valves on
the P&ID's
(manifold).
b. A manual valve to reactor #3 was not shown on the P&ID.

View DPC ENTERPRISES's full OSHA safety record →

HYERA INC