LAREDO, TX —
OSHA Inspection: ORION DRILLING COMPANY LLC, RIG#12
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of ORION DRILLING COMPANY LLC, RIG#12 in GALVAN RANCH A359H, LAREDO, TX 78040 (NAICS 213111). OSHA activity number 316301928.
Where did this inspection happen?
- Establishment
- ORION DRILLING COMPANY LLC, RIG#12
- Site address
- GALVAN RANCH A359H
- City
- LAREDO
- State
- TX
- ZIP
- 78040
- Mailing
- 674 FLATO RD, CORPUS CHRISTI, TX 78405
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213111
- SIC code (legacy)
- 1381
- Employees
- 12
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.132 D02
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $4900.00
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing, or likely to cause, death or serious physical harm to employees in that employees were exposed to struck-by hazards resulting from the release of hazardous energy: On or about January 11, 2012, and at other times prior thereto, at this site, the employer did not implement a hazardous energy control program to protect employees from the unexpected release of hazardous energy (hydraulic) during equipment servicing. Among others, one feasible means of abatement is to implement a hazardous energy control program in accordance with the American Petroleum Institute (API) RP 54 - 'Recommended Practice for Occupational Safety for Oil and Gas Well Drilling and Servicing Operations" (1999, 2007) and the ANSI Z244.1 - "Control of Hazardous Energy Lockout/Tagout and Alternative Methods" (2003, 2008). This implementation should include steps, including, but not limited to: a.removal of the stored energy of high pressure hydraulic fluid prior to adjusting and replacing faulty machine parts b.review the program on at least an annual basis, including review of field applications, for effectiveness and completeness c.ensuring the performance of job safety analysis (JSA, JHA) between site/host and visiting employers.
Recent events (2)
- — I (S) $4900.00
- — Z (S) $4900.00
1910.151 A
- Issued
- Abate by
- Penalty
- Initial $4900.00
Recent events (2)
- — I (S)
- — Z (S) $4900.00
More inspections in this industry (NAICS 213111)
JAL, NM—2026-07-01 00:00:00
HELMERICH & PAYNE, IDC
LAREDO, TX—2026-06-29 00:00:00
AXIS ENERGY SERVICES, LLC
MCALESTER, OK—2026-06-18 00:00:00
SANGUINE GAS EXPLORATION, LLC
MOUNT PLEASANT, MI—2026-06-15 00:00:00
BIGARD & HUGGARD DRILLING INC
MOUNT PLEASANT, MI—2026-06-15 00:00:00
BIGARD & HUGGARD DRILLING INC
More inspections in TX
RICHMOND, TX—2026-07-17 00:00:00
CORNELIUS NURSERIES, INC.
HOUSTON, TX—2026-07-17 00:00:00
HOLLOWAY HOUSTON, INC.
BONHAM, TX—2026-07-17 00:00:00
VOLUNTARY PURCHASING GROUPS, INC.
SNYDER, TX—2026-07-16 00:00:00
RNWBL
WICHITA FALLS, TX—2026-07-16 00:00:00
UNITED RENTALS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 316301928.