STAFFORD, VA —
OSHA Inspection: DGF AUTO RECYCLING, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DGF AUTO RECYCLING, LLC in 164 NORMAN RD., STAFFORD, VA 22554 (NAICS 423930). OSHA activity number 316731652.
Where did this inspection happen?
- Establishment
- DGF AUTO RECYCLING, LLC
- Site address
- 164 NORMAN RD.
- City
- STAFFORD
- State
- VA
- ZIP
- 22554
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- SIC code (legacy)
- 5093
- Employees
- 30
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
2 citations on file for this inspection.
510001 A
- Issued
- Abate by
- Penalty
- Initial $735.00 · Current $514.00 Reduced
General-duty citation text
Title 40.1-51.1(a) Code of Virginia: The employer, DGF Auto Recycling, LLC, did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious bodily harm to employees in that employees were exposed to a potential crushing hazard. At 164 Norman Dr. Stafford, VA, DGF Auto Recycling LLC, did not ensure that employees working underneath vehicles were provided with a method of protection so that the engine or other components would not fall on top of employees. Employees were using shop built welded rims as a jack stand to hold vehicles in place. According to the American Society of Mechanical Engineers (ASME), PALD-2009, Safety Standard for Portable Automotive Lifting Devices, Part 4, a vehicle support stand can only be used if it meets the following guidelines: A: 4-2.7 Proof Load- All vehicle support stands shall be capable of performing the proof load test of para. 4-4.1.2 with a load of 200of rated capacity. B: 4-3.1 Safety Markings- Safety markings shall conform to the ANSI Z535 series of standards. a) Study, understand, and follow all instructions before operating this device. b) Do not exceed rated capacity. c) Use only on hard level surface. d) Center load on saddle. C: 4-4.1 Proof Tests- For each design or design change that may affect the stand's ability to meet this Standard, sample stands built to design specifications shall be proof tested. To conform with this Standard, the stands shall perform to design specifications and no functional damage shall occur, nor shall operational characteristics be detrimentally affected. For stands that incorporate multiple load holding devices within a single assembly, each device shall be tested independently.
Recent events (2)
- — I (S) $514.00
- — Z (S) $735.00
1910.151 B
- Issued
- Abate by
More inspections in this industry (NAICS 423930)
DETROIT, MI—2026-07-15 00:00:00
STRONG STEEL PRODUCTS, LLC
OGDEN, UT—2026-07-10 00:00:00
TEAR A PART AUTO RECYCLING
GARNER, NC—2026-07-09 00:00:00
161490 - CAROLINA METAL RECYCLERS, LLC
JOPLIN, MO—2026-07-07 00:00:00
SERVICE RECYCLING - NORTH PLANT
FORT WORTH, TX—2026-07-02 00:00:00
199 RECYCLING INC.
More inspections in VA
VIRGINIA BEACH, VA—2026-07-16 00:00:00
GRAND SLAM CAR WASH
KILMARNOCK, VA—2026-07-16 00:00:00
CARR'S TIRE SERVICE
COLLINSVILLE, VA—2026-07-16 00:00:00
ACES, LLC
PORTSMOUTH, VA—2026-07-15 00:00:00
DACS INC
MANASSAS, VA—2026-07-15 00:00:00
VAFMC LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 316731652.