GREENSBORO, NC —
OSHA Inspection: O'CHARLEY'S LLC #908
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of O'CHARLEY'S LLC #908 in 4505 LANDOVER ROAD, GREENSBORO, NC 27404 (NAICS 722110). OSHA activity number 317465466.
Where did this inspection happen?
- Establishment
- O'CHARLEY'S LLC #908
- Site address
- 4505 LANDOVER ROAD
- City
- GREENSBORO
- State
- NC
- ZIP
- 27404
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 722110
- SIC code (legacy)
- 5812
- Employees
- 55
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
2 citations on file for this inspection.
95012901
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1850.00 Reduced
General-duty citation text
North Carolina General Statute, 95-129(1), of the Occupational Safety and Health Act of North Carolina: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to carbon monoxide levels above the permissible exposure limit: a)facility - employees were exposed to levels of carbon monoxide above the permissible exposure limit (PEL) on January 3, 2014. The Greensboro Fire Department reported monitoring carbon monoxide levels of 300 to 400 ppm on the evening of January 3, 2014. Eighteen employees complained of symptoms including but not limited to headaches, nausea, vomiting, rapid heartbeat, and dizziness and were seen / treated by Guilford Co. EMS and Moses Cone ER over two days for carbon monoxide exposure. On December 3, 2013 the HVAC contractor, STR Mechanical, conducted an inspection of the HVAC equipment and found / reported to O'Charley's #908 that the Trane M#YCD102C3HOAC / S#NS1100616D had a hole in the heat exchanger. The employer continued to operate the place of employment knowing the heat exchanger, a source of carbon monoxide, had a hole in it. ABATEMENT NOTE: Among other methods, one feasible and acceptable abatement method to correct this hazard would be to incorporate / install carbon monoxide detectors throughout the restaurant to warn of increasing levels of carbon monoxide and prevent overexposure situations.e
Recent events (2)
- — I (S) $1850.00
- — Z (S) $2800.00
1910.1000 A02
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1850.00 Reduced
Recent events (2)
- — I (S) $1850.00
- — Z (S) $2800.00
More inspections in this industry (NAICS 722110)
CAMAS, WA—2026-07-15 00:00:00
WA317992085 - CEDAR STREET BAGEL COMPANY
VANCOUVER, WA—2026-07-15 00:00:00
WA317992083 - HANDMADE LLC
LAKE STEVENS, WA—2026-07-07 00:00:00
WA317991945 - LEGATO INC
SEATTLE, WA—2026-07-07 00:00:00
WA317991877 - DREAMLAND BAR & DINER LLC
SCRANTON, KY—2026-06-24 00:00:00
69250 - SHMS FAMILY LLC
More inspections in NC
KERNERSVILLE, NC—2026-07-15 00:00:00
161552 - EDC, INC.
FRANKLINTON, NC—2026-07-15 00:00:00
161551 - LINDSAY PRECAST, LLC
RALEIGH, NC—2026-07-14 00:00:00
161550 - SUNRISE SENIOR LIVING MANAGEMENT, INC.
LAURINBURG, NC—2026-07-14 00:00:00
161549 - AMERICAN WOOD FIBERS, INC.
RURAL HALL, NC—2026-07-14 00:00:00
161546 - CAVERT WIRE COMPANY, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 317465466.