Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: NW INDUSTRIAL MECHANICS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NW INDUSTRIAL MECHANICS, INC. in 951 HWY 30, HEYBURN, ID 83336 (NAICS 238220). OSHA activity number 330017989.

Watch NW Industrial Mechanics, INC. — free Get an email when a new federal OSHA severe-injury report for NW Industrial Mechanics, INC. is published. One employer, no account, unsubscribe in one click.
Site address
951 HWY 30
City
HEYBURN
State
ID
ZIP
83336
Mailing
POB 6091, VANCOUVER, WA 98668
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
6
Ownership type
A

3 citations on file for this inspection.

1926.501 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $3000.00 · Current $3000.00
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:    a) Northwest corner of structure at roof level; On or about 3/23/11 and at times prior thereto, two employees without a means of fall protection were walking/working at distances of 8 or less feet from the roof edge while assisting a crane in hoisting/setting a large metal frame upon the roof deck.    Note: Abatement certification is NOT required for this item.
Recent events (1)
  • — Z (S) $3000

1926.100 A

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns:    a) Northwest corner of stucture at roof level; On or about 3/23/11 and at times prior thereto, two employees without hard hats were assisting a crane in hoisting/setting a large metal frame upon the roof deck.    Note: Abatement certification is NOT required for this item.
Recent events (1)
  • — Z (O) $0

1926.1428 A

Other-than-serious 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1428(a): The employer of the signal person did not ensure that each signal person met the Qualification Requirements (paragraph (c) of this section) prior to giving any signals. This requirement must be met by using either Option (1) or Option (2) of this section.    a) Northwest corner of structure at roof level; On or about 3/23/11 and at times prior thereto, an employee not meeting the qualification requirements was signaling a crane that was hoisting/setting a large metal frame onto the roof deck.    Note: Abatement certification is NOT required for this item.