OSHA Inspection: PHOENIX CONSTRUCTION COMPANY OF ILLINOIS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PHOENIX CONSTRUCTION COMPANY OF ILLINOIS, INC. in 1919 GREY AVE, EVANSTON, IL 60202 (NAICS 238350). OSHA activity number 330630195.

Watch Phoenix Construction Company OF Illinois, INC. — free Get an email when a new federal OSHA severe-injury report for Phoenix Construction Company OF Illinois, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1919 GREY AVE
City
EVANSTON
State
IL
ZIP
60202
Mailing
1052 N. CLAREMONT, PALATINE, IL 60074
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238350
Employees
2
Ownership type
A

4 citations on file for this inspection.

1926.405 B02

Serious Gravity 5 3 instances 1 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $1080.00 Reduced
29 CFR 1926.405(b)(2): Outlet boxes were not provided with covers, faceplates, or fixture canopies:    a) The employer did not guard or otherwise protect employees from accidental contact with energized outlets and switches operating at 120 volts.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1080
  • — Z (S) $2400

1926.416 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4200.00 · Current $1870.00 Reduced
29 CFR 1926.416(a)(1):  No employer shall permit an employee to work in such proximity to any part of an electric powercircuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock bydeenergizing the circuit and grounding it or by guarding it effectively by insulation or other means:    a) Employees were exposed to electrical hazards where carpentry work was conducted within 2 feet of a service drop power line having a voltage rating of 120/240 volts.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1870
  • — Z (S) $4200

1926.501 B13

Serious Gravity 5 4 instances 1 exposed
Issued
Abate by
Penalty
Initial $3000.00 · Current $1350.00 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet(1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provisionin paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it isinfeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets therequirements of paragraph (k) of 1926.502.Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fallprotection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complieswith 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.    a) East Wall - Employees were not protected from the hazard of falling from second story wall openings.    b) North Wall - Employees were not protected from the hazard of falling from second story wall openings.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1350
  • — Z (S) $3000

1926.416 E01

Other-than-serious 3 instances 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables shall not be used:    a) Worn and frayed electrical cords were used to supply electrical power to tools and equipment at the site.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330630195.