PEYTON, CO —
OSHA Inspection: BIG R SUPPLY
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BIG R SUPPLY in 14155 E. HIGHWAY 24, PEYTON, CO 80831 (NAICS 453998). OSHA activity number 330921891.
Where did this inspection happen?
- Establishment
- BIG R SUPPLY
- Site address
- 14155 E. HIGHWAY 24
- City
- PEYTON
- State
- CO
- ZIP
- 80831
- Mailing
- 14155 E. HIGHWAY 24, PEYTON, CO 80831
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 453998
- Employees
- 32
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.176 B
- Issued
- Abate by
- Penalty
- Initial $3060.00 · Current $1530.00 Reduced
General-duty citation text
29 CFR 1910.176(b): Storage of material created a hazard: a) On or about July 12, 2011 and at times prior, employees were exposed to hazards associated with storage of material on racks in the feed barn in that, rack columns and footings were bearing on unstable surfaces including cracked and deteriorated pieces of wood. Rack columns were also not bolted to the floor in the feed barn and receiving area. Abatement Note: Abatement certification is required for this item. See enclosed Sample Abatement Certification Letter.
Recent events (2)
- — I (S) $1530
- — Z (S) $3060
1910.178 P01
- Issued
- Abate by
- Penalty
- Initial $2295.00 · Current $1148.00 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s) a) On or about July 12, 2011 and at times prior, a powered industrial truck (Real Lift R-25) in use at the site was in unsafe operating condition in that, it had a broken and non-functional horn. Abatement Note: Abatement certification is required for this item. See enclosed Sample Abatement Certification Letter.
Recent events (2)
- — I (S) $1147.5
- — Z (S) $2295
1910.303 B02
- Issued
- Penalty
- Initial $1951.00 · Current $976.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) On or about July 12, 2011 and at times prior, a relocatable power tap (power strip) in the customer service area was plugged into another relocatable power tap (power strip) and not into a permanent receptacle as intended.
Recent events (2)
- — I (O) $975.5
- — Z (S) $1950.75
1904.29 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1904.29(b)(1): A Log of all recordable work-related injuries and illnesses (OSHA Form 300 or equivalent), was not completed in the detail as required by the regulation: a) On or about July 12, 2011 and at times prior, the OSHA form 300 logs for 2008, 2010 and 2011 were not completed in sufficient detail specifically as follows: 1. Both entries for 2008 contained deficiencies as follows: Columns (C) and (E) were left blank. Column (F) did not contain a description of the injury/illness. No boxes were checked in columns (G) through (J). 2. The entry for 2010 contained deficiencies as follows: Column (E) was left blank. Column (F) did not contain a description of the injury/illness. No boxes were checked in columns (G) through (J). 3. The entry for 2011 contained deficiencies as follows: Column (F) did not contain a description of the injury/illness. No boxes were checked in columns (G) through (J). Abatement Note: Abatement certification is required for this item. See enclosed Sample Abatement Certification Letter.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV D
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and cables were attached to building surfaces: a) On or about July 12, 2011 and at times prior, the power cord for the compactor was attached to the ceiling and routed to a receptacle on the opposite wall. Abatement Note: Abatement certification is required for this item. See enclosed Sample Abatement Certification Letter.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at BIG R SUPPLY
FALCON, CO—2023-01-19 00:00:00
BIG R SUPPLY
SPOKANE, WA—1991-07-30 00:00:00
BIG R SUPPLY
View BIG R SUPPLY's full OSHA safety record →
More inspections in this industry (NAICS 453998)
COAMO, PR—2026-07-16 00:00:00
CARRIBEAN RETAIL VENTURE'S INC
NEW BRITAIN, CT—2026-07-14 00:00:00
JANANII, LLC
QUINCY, FL—2026-07-13 00:00:00
WALMART
SUMMERVILLE, SC—2026-07-09 00:00:00
77568 - RACK ROOM SHOES
HARLEYSVILLE, PA—2026-07-09 00:00:00
TRACTOR SUPPLY CO.
More inspections in CO
FORT COLLINS, CO—2026-07-16 00:00:00
GLOZER, LLC
BROOMFIELD, CO—2026-07-16 00:00:00
WAVELYNX TECHNOLOGIES LLC
COLORADO SPRINGS, CO—2026-07-15 00:00:00
ELMER CONTRACTOR LLC
SHERIDAN, CO—2026-07-15 00:00:00
JOHN'S COLLISION REPAIR, INC.
CENTENNIAL, CO—2026-07-15 00:00:00
BRAKES PLUS, INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330921891.