BOZEMAN, MT —
OSHA Inspection: JEFF CLEMENTS ROOFING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JEFF CLEMENTS ROOFING in 2340 BOYLON LOT 34, BOZEMAN, MT 59718 (NAICS 238160). OSHA activity number 330971219.
Where did this inspection happen?
- Establishment
- JEFF CLEMENTS ROOFING
- Site address
- 2340 BOYLON LOT 34
- City
- BOZEMAN
- State
- MT
- ZIP
- 59718
- Mailing
- 223 CIRQUE DR., BOZEMAN, MT 59718
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $1800.00 · Current $1260.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet(1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer did not develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.
Recent events (2)
- — I (S) $1260
- — Z (S) $1800
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder was not secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, was not provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16 00:00:00
MARVIN PINERA
CARSON CITY, NV—2026-07-16 00:00:00
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16 00:00:00
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16 00:00:00
CARLOS CHE
BALTIMORE, MD—2026-07-16 00:00:00
VAL CONSTRUCTION INC
More inspections in MT
HELENA, MT—2026-06-23 00:00:00
SUMMIT ROOFING, INC.
BUTTE, MT—2026-06-22 00:00:00
B.B. GLASS, INC.
BUTTE, MT—2026-06-22 00:00:00
HUNTER BROTHERS CONSTRUCTION
GREAT FALLS, MT—2026-06-22 00:00:00
TC GLASS INC
HELENA, MT—2026-06-17 00:00:00
VANILLA BEAN BAKERY, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330971219.