NILES, IL —
OSHA Inspection: JOHN'S SEWER SERVICE LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JOHN'S SEWER SERVICE LLC in 8406 OSCEOLA, NILES, IL 60714 (NAICS 237110). OSHA activity number 330976622.
Where did this inspection happen?
- Establishment
- JOHN'S SEWER SERVICE LLC
- Site address
- 8406 OSCEOLA
- City
- NILES
- State
- IL
- ZIP
- 60714
- Mailing
- 8273 N. OZANAM, NILES, IL 60714
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 6
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.100 A
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: a) Employees working in a trench were not wearing protective helmets where there was a possible danger of head injury from falling objects. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $1200
- — Z (S) $2400
1926.651 C02
- Issued
- Abate by
- Penalty
- Initial $3000.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees: a) Employees were not provided with a safe means of egress when working in a trench with a depth of approximately 6.7 feet. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $1500
- — Z (S) $3000
1926.651 J02
- Issued
- Abate by
- Penalty
- Initial $3000.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary: a) Employees were working in a trench where the spoil pile was placed and kept at the edge of the excavation. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $1500
- — Z (S) $3000
1926.651 K01
- Issued
- Abate by
- Penalty
- Initial $3000.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems: a) Employer did not provide a competent person to conduct inspections where employees were exposed to the hazards associated with trenching and excavation work. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $1500
- — Z (S) $3000
1926.652 A01
- Issued
- Abate by
- Penalty
- Initial $4200.00 · Current $2300.00 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(b) or 1926.652(c): a) Employees were not protected from the hazard of cave-in while working in a trench measuring approximately 6.7 feet in depth. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $2300
- — Z (S) $4200
More inspections in this industry (NAICS 237110)
CHANDLER, AZ—2026-07-16 00:00:00
PREMIER UNDERGROUND CONSTRUCTION LLC
HIGHLAND PARK, IL—2026-07-16 00:00:00
UNITED PLUMBING AND DRAIN, INC.
CHICAGO, IL—2026-07-15 00:00:00
SUSTAINABLE SEWER & WATER INC.
LAKE FOREST, IL—2026-07-15 00:00:00
GREVERS CORPORATION DBA NORTH SHORE BORING
CHEYENNE, WY—2026-07-15 00:00:00
AZTEC CONSTRUCTION
More inspections in IL
DEERFIELD, IL—2026-07-16 00:00:00
JOHN BURNS CONSTRUCTION COMPANY, LLC
BANNOCKBURN, IL—2026-07-16 00:00:00
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
BANNOCKBURN, IL—2026-07-16 00:00:00
ROOFING H.P. LLC
HIGHLAND PARK, IL—2026-07-16 00:00:00
UNITED PLUMBING AND DRAIN, INC.
FRANKLIN PARK, IL—2026-07-16 00:00:00
B & M PLASTIC INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330976622.