Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: OHIO VALLEY CABLE SERVICES

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of OHIO VALLEY CABLE SERVICES in 1030 FREEWAY DRIVE, COLUMBUS, OH 43229 (NAICS 517510). OSHA activity number 330986480.

Watch Ohio Valley Cable Services — free Get an email when a new federal OSHA severe-injury report for Ohio Valley Cable Services is published. One employer, no account, unsubscribe in one click.
Site address
1030 FREEWAY DRIVE
City
COLUMBUS
State
OH
ZIP
43229
Mailing
1030 FREEWAY DRIVE, COLUMBUS, OH 43229
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
517510
Employees
235
Ownership type
A

2 citations on file for this inspection.

1910.138 A

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2295.00 · Current $1607.00 Reduced
29 CFR 1910.138(a):     General requirements. Employers shall select and require employees to use appropriate hand protectionwhen employees' hands are exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasions;punctures; chemical burns; thermal burns; and harmful temperature extremes.    a. In the warehouse, forklift operators who were exposed to sulfuric acid while performing battery maintenance were provided with latex gloves.
Recent events (2)
  • — I (S) $1606.5
  • — Z (S) $2295

1910.305 A01 I

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2295.00 · Current $1607.00 Reduced
29 CFR 1910.305(a)(1)(i):     Metal raceways, cable trays, cable armor, cable sheath, enclosures, frames, fittings, and other metal noncurrent-carrying parts that are to serve as grounding conductors, with or without the use of supplementary equipment grounding conductors, shall be effectively bonded where necessary to ensure electrical continuity and the capacity to conduct safely any fault current likely to be imposed on them. Any nonconductive paint, enamel, or similar coating shall be removed at threads, contact points, and contact surfaces or be connected by means of fittings designed so as to make such removal unnecessary.    a. In the warhouse, the metal conduit surrounding the flexible electrical cable on the Kodiak charger was not adequately bonded to its fitting.
Recent events (2)
  • — I (S) $1606.5
  • — Z (S) $2295

KENWORTH