COEUR D ALENE, ID —
OSHA Inspection: YOST MOONEY & PUGH CONTRACTORS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of YOST MOONEY & PUGH CONTRACTORS, INC. in W. RIVERSTONE DR., COEUR D ALENE, ID 83814 (NAICS 236220). OSHA activity number 330988098.
Where did this inspection happen?
- Establishment
- YOST MOONEY & PUGH CONTRACTORS, INC.
- Site address
- W. RIVERSTONE DR.
- City
- COEUR D ALENE
- State
- ID
- ZIP
- 83814
- Mailing
- PO BOX 2983, SPOKANE, WA 99220
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 15
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B01
- Issued
- Penalty
- Initial $1734.00 · Current $867.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) On the southeast corner of the building under construction, on September 9, 2011 and at times prior thereto, an "L" shaped concrete retaining wall at grade level was 13' above the lower level and unguarded along both sides. b) On the northeast corner of the building under construction, on September 9, 2011 and at times prior thereto, a leading edge of the first floor was 13' above the next level and was without fall protection. NOTE: Abatement certification is NOT required for these items.
Recent events (2)
- — I (S) $867
- — Z (S) $1734
1926.1052 C01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: a) On the southeast face of the building, on September 9, 2011, and at times prior thereto, a stairway descending 13 ft. from grade level to the next lower level, was not equipped with a handrail. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 236220)
ROCHESTER, NH—2026-07-17 00:00:00
STAR CONSTRUCTION SVS INC
WHITESTOWN, IN—2026-07-17 00:00:00
CENTRAL WELDING INC
MOUNTAIN LAKES, NJ—2026-07-17 00:00:00
JOHN CARUSO BUILDERS LLC
FAIRFAX, VA—2026-07-17 00:00:00
RYCON CONSTRUCTION, INC.
SHAWNEE, KS—2026-07-16 00:00:00
BRATTON BROTHERS CONTRACTING INC
More inspections in ID
MERIDIAN, ID—2026-07-17 00:00:00
COBRA'S ROOFING LLC
MERIDIAN, ID—2026-07-17 00:00:00
CARRILLO CONSTRUCTION LLC
MERIDIAN, ID—2026-07-17 00:00:00
SEVY BROTHERS CONSTRUCTION LLC
MERIDIAN, ID—2026-07-17 00:00:00
CBH HOMES
BOISE, ID—2026-07-16 00:00:00
RAYMOND MANAGEMENT COMPANY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330988098.