PEYTON, CO —
OSHA Inspection: PREMIER ROOFING COMPANY LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PREMIER ROOFING COMPANY LLC in 11365 CRANSTON AVE, PEYTON, CO 80831 (NAICS 238160). OSHA activity number 331064931.
Where did this inspection happen?
- Establishment
- PREMIER ROOFING COMPANY LLC
- Site address
- 11365 CRANSTON AVE
- City
- PEYTON
- State
- CO
- ZIP
- 80831
- Mailing
- 2570 W. 8TH AVE., DENVER, CO 80204
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 1
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.102 A01
- Issued
- Abate by
- Penalty
- Initial $3000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. a) On or about September 17, 2011 and at times prior, Premier Roofing Co., LLC as controlling contractor, did not ensure that Pacheco Roofing (subcontractor) protected their employees from eye hazards. Employees were using pneumatic nailers to install shingles without wearing eye protection.
Recent events (2)
- — I (S) $0
- — Z (S) $3000
1926.307 D01
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.307(d)(1): Pulley(s) with part(s) seven feet (2.128 m) or less from the floor or work platform were not guarded in accordance with the requirements specified in paragraphs (m) and (o) of this section: a) On or about September 17, 2011 and at times prior, Premier Roofing Co., LLC as controlling contractor, did not ensure that Pacheco Roofing (subcontractor) protected their employees from mechanical power hazards. A portable compressor, used to power pneumatic nailers for shingle installation, had no guarding for the belt and pulley.
Recent events (2)
- — I (S) $0
- — Z (S) $2400
1926.307 E01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.307(e)(1)(i): Where both runs of a horizontal belt were 42 inches (106.68 cm) or less from the floor, the belt was not fully enclosed: a) On or about September 17, 2011 and at times prior, Premier Roofing Co., LLC as controlling contractor, did not ensure that Pacheco Roofing (subcontractor) protected their employees from mechanical power-transmission hazards. The portable compressor, used to produce air for pneumatic nailers, did not have guards installed over the belt and pulleys.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $4200.00 · Current $3000.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502. a) On or about September 17, 2011 and at times prior, Premier Roofing Co, LLC as controlling/exposing contractor, did not ensure that its employees and employees of Pacheco Roofing (subcontractor) were protected from fall hazards from a roof. The crew installing the shingles was using no type of fall protection system, neither did they have a plan meeting the requirements of paragraph (k) of section 1926.502.
Recent events (2)
- — I (S) $3000
- — Z (S) $4200
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $3000.00 · Current $2500.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) On or about September 17, 2011 and at times prior, Premier Roofing Co., LLC as controlling/exposing contractor, did not ensure that its employees and employees of Pacheco Roofing (subcontractor) did not ensure that employees were protected from ladder hazards. The roofing crew did not properly set up the ladder used to access the roof. The side rails were not extended at least 3 feet above the landing.
Recent events (2)
- — I (S) $2500
- — Z (S) $3000
1926.1053 B06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(6): Ladders were used on surfaces which were not stable and level: a) On or about September 17, 2011 and at times prior, Premier Roofing Co., LLC as controlling/exposing contractor, did not ensure that its employees and employees of Pacheco Roofing were protected from ladder use hazards. The ladder, used to access the roofing level, was set up on hard packed ground without being secured at top or bottom.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B10
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(10): The tops of a non-self-supporting ladder were not placed with the two rails supported equally: a) On or about September 17, 2011 and at times prior, Premier Roofing Co., LLC as controlling/exposing contractor, did not ensure that its employees and employees of Pacheco Roofing (subcontractor) were protected from ladder use hazards. The ladder, used to access the roof area, was not set with equal support from both rails due to gable end slope.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at PREMIER ROOFING COMPANY LLC
LONE TREE, CO—2020-09-18 00:00:00
PREMIER ROOFING COMPANY LLC
DENVER, CO—2017-03-22 00:00:00
PREMIER ROOFING COMPANY LLC
AURORA, CO—2015-12-21 00:00:00
PREMIER ROOFING COMPANY LLC
FORT COLLINS, CO—2014-12-02 00:00:00
PREMIER ROOFING COMPANY LLC
FORT COLLINS, CO—2014-07-25 00:00:00
PREMIER ROOFING COMPANY LLC
View PREMIER ROOFING COMPANY LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
PORTLAND, OR—2026-07-17 00:00:00
317744797 - JBC ROOFING LLC
MERIDIAN, ID—2026-07-17 00:00:00
COBRA'S ROOFING LLC
SYRACUSE, NY—2026-07-17 00:00:00
NAMICELA HOME SOLUTIONS INC
BRADLEY, IL—2026-07-16 00:00:00
JUAN CRUZ DBA ROOFBOYS LLC
PONCE INLET, FL—2026-07-16 00:00:00
RESOLUTE ROOFING LLC
More inspections in CO
FORT COLLINS, CO—2026-07-16 00:00:00
GLOZER, LLC
BROOMFIELD, CO—2026-07-16 00:00:00
WAVELYNX TECHNOLOGIES LLC
COLORADO SPRINGS, CO—2026-07-15 00:00:00
ELMER CONTRACTOR LLC
SHERIDAN, CO—2026-07-15 00:00:00
JOHN'S COLLISION REPAIR, INC.
CENTENNIAL, CO—2026-07-15 00:00:00
BRAKES PLUS, INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331064931.