Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: PETER KOBIERSKI

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PETER KOBIERSKI in 3005 N. DAMEN AVE, CHICAGO, IL 60657 (NAICS 238140). OSHA activity number 331066613.

Watch Peter Kobierski — free Get an email when a new federal OSHA severe-injury report for Peter Kobierski is published. One employer, no account, unsubscribe in one click.
Establishment
PETER KOBIERSKI
Site address
3005 N. DAMEN AVE
City
CHICAGO
State
IL
ZIP
60657
Mailing
2916 N. HARLEM AVE., ELMWOOD PARK, IL 60707
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
5
Ownership type
A

5 citations on file for this inspection.

1926.451 D05 III

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3000.00 · Current $1200.00 Reduced
29 CFR 1926.451(d)(5)(iii):  Suspension scaffold support devices such as cornice hooks, roof hooks, roof irons, parapet clamps, or similar devices shall be secured against movement by tiebacks installed at right angles to the face of the building or structure, or opposing angle tiebacks shall be installed and secured to a structurally sound point of anchorage on the building or structure.  Sound points of anchorage include structural members, but do not include standpipes, vents, other piping systems, or electrical conduit:    a)  On or about September 19, 2011, the cornice hooks supporting a two point suspension scaffold were not tied back.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1200
  • — Z (S) $3000

1926.451 G04 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $0.00 Reduced
29 CFR 1926.451(g)(4)(iv):  When midrails are used, they shall be installed at a height approximately midway between the topedge of the guardrail system and the platform surface:    a)  On or about September 29, 2011, no midrail was present on the two point suspension scaffold.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $2400

1926.451 D16

Serious Gravity 5 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $3000.00 · Current $1200.00 Reduced
29 CFR 1926.451(d)(16): In addition to the normal operating brake, suspension scaffold power-operated hoists and manually operated hoists did not have a braking device or locking pawl which engages automatically when a hoist makes either of the following uncontrolled movements: an instantaneous change in momentum or an accelerated overspeed:    a)  Employees were working from a two-point adjustable suspension scaffold that did not have a braking device or locking pawl.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1200
  • — Z (S) $3000

1926.451 D17

Serious Gravity 5 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(d)(17):  Manually operated hoists did not have a positive crank force to descend:    a)  Employees were working from a two-point adjustable suspension scaffold where the manually operated hoist did not have a positive crank force to descend.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $960.00 Reduced
29 CFR 1926.1053(b)(1):  Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:    a)  The extension ladder being used to access to the roof deck did not extend 3 feet above the landing being accessed.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $960
  • — Z (S) $2400