Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: L2 INSULATION, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of L2 INSULATION, INC. in 390 GUN FIGHTER AVE., MOUNTAIN HOME A F B, ID 83648 (NAICS 238310). OSHA activity number 331067272.

Watch L2 Insulation, INC. — free Get an email when a new federal OSHA severe-injury report for L2 Insulation, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
L2 INSULATION, INC.
Site address
390 GUN FIGHTER AVE.
City
MOUNTAIN HOME A F B
State
ID
ZIP
83648
Mailing
393 S. W. 7TH AVE., MERIDIAN, ID 83642
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238310
Employees
2
Ownership type
A

7 citations on file for this inspection.

1910.134 C01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1800.00 · Current $900.00 Reduced
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (Construction Reference 1926.103)    a) Jobsite: On September 21, 2011, and times prior thereto, employees were spraying a two-part polyurethane foam insulation without a written respiratory protection program that addresses specific work-site procedures for required respirator use.    Note: Abatement certification is required for this item.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1800

1910.134 D01 III

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(d)(1)(iii): When the employer was unable to identify or reasonably estimate the employee exposure, the employer did not consider the atmosphere to be IDLH: (Construction Reference 1926.103):    a) Jobsite: On September 21, 2011, and times prior thereto, employees were spraying a two-part polyurethane foam insulation with a half-mask respirator and not a supply air respirator when the employer was unable to identify or reasonably estimate the employee exposure, and the employer did not consider the atmosphere to be IDLH.       Note: Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 D03 III B 2

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(d)(3)(iii)(B)(2):  The employer did not implement a change schedule for respirators not equipped with an ESLI that would ensure cartridges were changed before the end of their service life:    a) Jobsite: On September 21, 2011, and times prior thereto, employees were spraying a two-part polyurethane foam insulation without a written respiratory protection program that addresses filter cartridge change-out based on the chemical, type of cartridge, and hours of use.     Note:  Abatement certification is required or this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (Construction Reference 1926.103)    a) Jobsite: On September 21, 2011, and times prior thereto, employees were spraying a two-part polyurethane foam insulation without a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator.    Note: Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): (Construction Reference 1926.103)    a) Jobsite: On September 21, 2011, and times prior thereto, employees were spraying a two-part polyurethane foam insulation with a half-mask respirator without a qualitative or quantitative fit test.     Note: Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 K

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(k): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary:  (Construction Reference 1926.103)    a) Jobsite: On September 21, 2011, and times prior thereto, employees were spraying a two-part polyurethane foam insulation without a written respiratory protection program that includes annual training or more often, if needed for  required respirator use.      Note: Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h): Employees were not provided effective information and training as specified in 29 CFR 1910.1200(h)(1) and -2 on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard was introduced in the work environment.    a) Jobsite: On September 21, 2011, and times prior thereto, employees were spraying a two-part polyurethane foam insulation without information and training on the hazards of the chemicals in use.      Note: Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

CBH HOMES