Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WHITEFISH VENTURES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of WHITEFISH VENTURES, INC. in 310 SUGARBOWL CIRCLE, WHITEFISH, MT 59937 (NAICS 236115). OSHA activity number 331077594.

Watch Whitefish Ventures, INC. — free Get an email when a new federal OSHA severe-injury report for Whitefish Ventures, INC. is published. One employer, no account, unsubscribe in one click.
Site address
310 SUGARBOWL CIRCLE
City
WHITEFISH
State
MT
ZIP
59937
Mailing
1399 WISCONSIN AVE., WHITEFISH, MT 59937
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
60
Ownership type
A

8 citations on file for this inspection.

1926.501 B06

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $4200.00 · Current $2100.00 Reduced
29 CFR 1926.501(b)(6):     "Ramps, runways, and other walkways." Each employee on ramps, runways, and other walkways were not protected from falling 6 feet (1.8 m) or more to lower levels by guardrail systems.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $4200

1926.1052 C01 II

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1052(c)(1)(ii):     Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with one stairrail system along each unprotected side or edge. Note: When the top edge of a stairrail system also serves as a handrail, paragraph (c)(7) of this section applies.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1052 C12

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1052(c)(12):     Unprotected sides and edges of stairway landings were not provided with guardrail systems. Guardrail system criteria are contained in subpart M of this part.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.651 C02

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $2450.00 Reduced
29 CFR 1926.651(c)(2):     Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.
Recent events (2)
  • — I (S) $2450
  • — Z (S) $4900

1926.651 J02

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $2450.00 Reduced
29 CFR 1926.651(j)(2):     Employees were not protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations.  Protection was not provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.
Recent events (2)
  • — I (S) $2450
  • — Z (S) $4900

1926.100 A

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.100(a):     Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, were not protected by protective helmets.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.651 K01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $2450.00 Reduced
29 CFR 1926.651(k)(1):     Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection was not conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.
Recent events (2)
  • — I (S) $2450
  • — Z (S) $4900

1926.652 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.652(a)(1):     Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

CBH HOMES