JOLIET, IL —
OSHA Inspection: KOZOL BROS, INC.
Programmed Related inspection · Safety discipline
At a glance
On , OSHA opened a programmed Related safety inspection of KOZOL BROS, INC. in 2010 S. BRIGGS ST., JOLIET, IL 60433 (NAICS 424810). OSHA activity number 331082594.
Where did this inspection happen?
- Establishment
- KOZOL BROS, INC.
- Site address
- 2010 S. BRIGGS ST.
- City
- JOLIET
- State
- IL
- ZIP
- 60433
- Mailing
- 2010 S. BRIGGS ST., JOLIET, IL 60433
What kind of inspection was it?
- Inspection type
- Programmed Related (J)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424810
- Employees
- 102
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.37 B06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.37(b)(6): Each exit sign must be illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color. Self-luminous or electroluminescent signs that have a minimum luminance surface value of at least .06 footlamberts (0.21 cd/m2) are permitted. Warehouse - On or about October 27, 2011, following exit signs were not illuminated as required, thereby exposing employees to the hazards associated with being able to egress in case of a fire. 1. North/center 2. West/center
Recent events (1)
- — Z (O) $0
1910.176 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.176(a): Use of mechanical equipment. Where mechanical handling equipment is used, sufficient safe clearances shall be allowed for aisles, at loading docks, through doorways and wherever turns or passage must be made. Aisles and passageways shall be kept clear and in good repair, with no obstruction across or in aisles that could create a hazard. Permanent aisles and passageways shall be appropriately marked. 1. Warehouse area - On or about October 27, 2011, the aisles and passageways were not appropriately marked.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 424810)
BEND, OR—2026-06-03 00:00:00
317744382 - COHO DISTRIBUTING LLC
GORHAM, ME—2026-05-28 00:00:00
NAPPI DISTRIBUTORS
YPSILANTI, MI—2026-04-22 00:00:00
O & W INC
ATLANTA, GA—2026-04-20 00:00:00
REYES FLEET MANAGEMENT, LLC
BAXTER, MN—2026-04-16 00:00:00
111081 - CHAS A BERNICK INCORPORATED
More inspections in IL
DEERFIELD, IL—2026-07-16 00:00:00
JOHN BURNS CONSTRUCTION COMPANY, LLC
BANNOCKBURN, IL—2026-07-16 00:00:00
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
BANNOCKBURN, IL—2026-07-16 00:00:00
ROOFING H.P. LLC
HIGHLAND PARK, IL—2026-07-16 00:00:00
UNITED PLUMBING AND DRAIN, INC.
FRANKLIN PARK, IL—2026-07-16 00:00:00
B & M PLASTIC INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331082594.