Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ENERSYS INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ENERSYS INC. in 12690 ELMWOOD AVE., CLEVELAND, OH 44111 (NAICS 334419). OSHA activity number 331098897.

Watch Enersys INC. — free Get an email when a new federal OSHA severe-injury report for Enersys INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ENERSYS INC.
Site address
12690 ELMWOOD AVE.
City
CLEVELAND
State
OH
ZIP
44111
Mailing
12690 ELMWOOD AVE., CLEVELAND, OH 44111
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334419
Employees
114
Ownership type
A

3 citations on file for this inspection.

1910.147 C01

Other-than-serious 1 instance 114 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $1000.00 Reduced
29 CFR 1910.147(c)(1):  The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative      On or before 10/26/2012 the employer failed to establish a program for the control of hazardous energy at the facility that consisted of employee training and annual aduits of the company's lock out procedures .  Employees conduct service and maintenance on equipment such as, but not limited to, the Selco bailer, the RBI Lam Shear, bake ovens(etc.), and other employee(s) working in the immediate area; are exposed to potentially hazardous energy.       NOTE: AN ENERGY CONTROL PROGRAM NEEDS TO INCLUDE THE FOLLOWING,      a. Individual lockout devices or tag out devices (e.g.: the placement, removal, transfer of       locks).    b. Documented employee training (both for authorized employees and affected employees).     c. Annual audits of the company's procedures outlining the purpose, scope, rules, and techniques utilized to control       hazardous energy.
Recent events (2)
  • — I (O) $1000
  • — Z (S) $3500

1910.212 A03 II

Serious Gravity 10 4 instances 114 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $3185.00 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):        On and before 10/26/2011 the point of operation, on the company's four (4 ) hydraulic compression crimp press tools, were not adequately guarded.
Recent events (2)
  • — I (S) $3185
  • — Z (S) $4900

1910.303 B02

Serious Gravity 1 1 instance 114 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $1365.00 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:          A metal outlet box, located in the production area of the facility, and designed for permanent installation was suspended from a flexible cord.
Recent events (2)
  • — I (S) $1365
  • — Z (S) $2100

View ENERSYS INC.'s full OSHA safety record →