CINCINNATI, OH —
OSHA Inspection: KWC CUSTOM HOMES, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of KWC CUSTOM HOMES, LLC in 3250 JEFFERSON AVE., CINCINNATI, OH 45220 (NAICS 236116). OSHA activity number 331103648.
Where did this inspection happen?
- Establishment
- KWC CUSTOM HOMES, LLC
- Site address
- 3250 JEFFERSON AVE.
- City
- CINCINNATI
- State
- OH
- ZIP
- 45220
- Mailing
- 1864 TOBEY ROAD, ATLANTA, GA 30319
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 17
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.20 B02
- Issued
- Penalty
- Initial $4200.00 · Current $3900.00 Reduced
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s) Workers were observed engaged in residential construction building a new multi-story, multi-unit student housing facility. Workers were exposed to potential electrocution and fall hazards in that a proper jobsite inspection by a competent person was not conducted.
Recent events (2)
- — I (S) $3900
- — Z (S) $4200
1926.503 A01
- Issued
- Penalty
- Initial $4200.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: Workers were engaged in residential type of construction activities building a multi-story, multi-unit student housing facility. Workers who were exposed to potential fall hazrds were not properly trained in fall protection criteria.
Recent events (2)
- — I (S) $0
- — Z (S) $4200
1926.1060 A
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, that enabled each employee to recognize hazards related to ladders and stairways, and that trained each employee in the procedures to be followed to minimize those hazards:
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.404 F06
- Issued
- Penalty
- Initial $3000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: Located on the ground area of Jefferson Street there was a air compressor connected to the temporayr electrical service with a 50.0 foot orange/black extension cord that was missing a grounding pin exposing workers to potential elecetrocution hazards.
Recent events (2)
- — I (S) $1000
- — Z (S) $3000
1926.501 B13
- Issued
- Penalty
- Initial $4200.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph (b) Workers were observed engaged in residential type of construction activities building a multi-story, multi-unit student housing facility. Workers were exposed to potential fall hazards in that proper fall protection systems were not utilized in three areas; 1) Roofers installing roofing material on the upper roof area, 2) Framers were working from the outside window sill area, nailing wooden 4.0x8.0 foot OSB siding material on the 2nd and 3rd story levels.
Recent events (2)
- — I (S) $1000
- — Z (S) $4200
1926.1053 B01
- Issued
- Penalty
- Initial $4200.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: Located on the Jefferson Street side area, workers were observed engaged in residential type of construction activities building a new multi-story, multi-unit student housing facility. Worker a utilized a 40.0 extension ladder as a means of access and egress. Workers accessing and exiting the roof area were exposed to potential fall hazards, from heights calculated to be 30.0 feet, in that the ladder did not extend 3.0 above the landing surface.
Recent events (2)
- — I (S) $1000
- — Z (S) $4200
More inspections in this industry (NAICS 236116)
JAMAICA PLAIN, MA—2026-07-15 00:00:00
PERFORMANCE BUILDING COMPANY INC.
DELAVAN, WI—2026-07-15 00:00:00
TERONOMY BUILDERS, INC.
QUINCY, MA—2026-07-15 00:00:00
UNITEDWOR VM CONTRACTOR CORP
HONOLULU, HI—2026-07-15 00:00:00
CS BUILDER LLC
NEWTON, MA—2026-07-14 00:00:00
DELLBROOK CONSTRUCTION, LLC
More inspections in OH
DAYTON, OH—2026-07-17 00:00:00
TEKNOL, INC.
PAYNE, OH—2026-07-16 00:00:00
LIPPERT
SUGARCREEK, OH—2026-07-16 00:00:00
PROVIA
CINCINNATI, OH—2026-07-16 00:00:00
GREENACRES FOUNDATION
WELLINGTON, OH—2026-07-16 00:00:00
WHIRLAWAY CORPORATION
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331103648.