On , OSHA opened a complaint safety inspection of PRE-HEAT INC. in 421 S. BUSINESS PARK DR., OOSTBURG, WI 53070 (NAICS 332410). OSHA activity number 331916486.

Watch Pre-Heat INC. — free Get an email when a new federal OSHA severe-injury report for Pre-Heat INC. is published. One employer, no account, unsubscribe in one click.
Establishment
PRE-HEAT INC.
Site address
421 S. BUSINESS PARK DR.
City
OOSTBURG
State
WI
ZIP
53070
Mailing
421 S. BUSINESS PARK DR., OOSTBURG, WI 53070
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332410
Employees
40
Ownership type
A

9 citations on file for this inspection.

1910.178 L01 I

Serious Gravity 5 6 exposed
Issued
Abate by
Penalty
Initial $2975.00 · Current $2000.00 Reduced
29 CFR 1910.178(l)(1)(i):     The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    a)    Up to six employees that drove lift truck but the company did not have a training program for lift truck operation at the time of the inspection.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2975

1910.184 I01

Other-than-serious 1 exposed
Issued
Abate by
Penalty
Initial $2380.00 · Current $0.00 Reduced
29 CFR 1910.184(i)(1):     Synthetic web sling(s) were not marked or coded to show rated capacities for each type of hitch and type of synthetic web material:    a)    Tags for nylon slings were not readable in bay #1 on white pipe and bay #2 along wall in storage area.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (S) $2380

1910.219 D01

Serious Gravity 5 1 exposed
Issued
Abate by
Penalty
Initial $2380.00 · Current $1500.00 Reduced
29 CFR 1910.219(d)(1):     Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    a)    Pulley was not guarded for Porter Cable air commpressor which was approximately 69" from the floor.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2380

1910.219 E01 I

Serious Gravity 5 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.219(e)(1)(i):     Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o):    a)    Belt was not guarded for Porter Cable air commpressor which was approximately 69" from the floor.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B04 I

Serious Gravity 5 1 exposed
Issued
Abate by
Penalty
Initial $2380.00 · Current $1500.00 Reduced
29 CFR 1910.253(b)(4)(i):     Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire; or    a)    Bay #2 South end had bottle storage with both oxygen and acetylene tanks stored together.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2380

1910.334 A02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2975.00 · Current $2000.00 Reduced
29 CFR 1910.334(a)(2)(i):     Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):    a)    Extension cords that were available for use in Bay #1 had damaged cords and/or missing ground pins on their plugs.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2975

1910.334 A02 II

Serious Gravity 5 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.334(a)(2)(ii):     There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service:      a)    Extension cords that were available for use in Bay #1 had damaged cords and/or missing ground pins on their plugs.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A03 II

Serious Gravity 5 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.334(a)(3)(ii):     Attachment plugs and receptacles were connected or altered in a manner which prevented proper continuity of the electric equipment grounding conductor at the point where plugs were attached to receptacles:  (a) (LOCATION) (IDENTIFY SPECIFIC OPERATIONS AND/OR CONDITIONS)      a)    Extension cords that were available for use in Bay #1 had damaged cords and/or missing ground pins on their plugs.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.179 M01

Other-than-serious 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.179(m)(1):     Thorough monthly inspections of rope conditions, with written, dated and signed reports, were not performed on the running ropes:    a)    Documented monthly inspections of wire rope conditions for 10 ton cranes, serial #143321 & 14332-2 was not being performed at the time of the inspection.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (O) $0