SADDLE BROOK, NJ —
OSHA Inspection: NORTH JERSEY TRUCK CENTER INC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of NORTH JERSEY TRUCK CENTER INC in 236 ROUTE 46 EAST, SADDLE BROOK, NJ 07663 (NAICS 811121). OSHA activity number 332429505.
Where did this inspection happen?
- Establishment
- NORTH JERSEY TRUCK CENTER INC
- Site address
- 236 ROUTE 46 EAST
- City
- SADDLE BROOK
- State
- NJ
- ZIP
- 07663
- Mailing
- 236 ROUTE 46 EAST, SADDLE BROOK, NJ 07663
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811121
- Employees
- 15
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.107 C06
- Issued
- Penalty
- Initial $2400.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1910.107(c)(6): Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spray area, and not separated therefrom by partitions, produced sparks under normal operating conditions and did not otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations: a) Spray Room: A pedestal fan was used within approximately 7 feet from the spray area and was not of an explosion proof type for use in a Class I, Division 2 Location, and was used to dry the newly painted surface of truck hoods and parts, on or about 02/02/2012.
Recent events (2)
- — I (S) $1200
- — Z (S) $2400
1910.107 D06
- Issued
- Penalty
- Initial $1800.00 · Current $900.00 Reduced
General-duty citation text
29 CFR 1910.107(d)(6): Belts entered the duct unless the belt and pulley within the duct or booth are thoroughly enclosed: a) Spray Room: The belt and pulley, which were driving the exhaust fan, entered the duct and was not enclosed to prevent them from coming into contact with flammable vapors such as, but not limited to, toluene, xylene, methylethyl ketone, and acetone, on or about 02/02/2011.
Recent events (2)
- — I (S) $900
- — Z (S) $1800
1910.107 J02
- Issued
- Penalty
- Initial $3600.00 · Current $1800.00 Reduced
General-duty citation text
29 CFR 1910.107(j)(2): Spray booths, rooms, or other enclosures used for spraying operations was alternately used for the purpose of drying by any arrangement which will cause a material increase in the surface temperature of the spray booth, room, or enclosure. a) Spray Room: The employee, who spray painted truck hood with a solvent that contained class I chemicals such as, but not limited to, toluene, xylene, and acetate, used multiple light bulbs to dry the newly painted surface, on or about 2/2/12.
Recent events (2)
- — I (S) $1800
- — Z (S) $3600
1910.134 I06
- Issued
- Abate by
- Penalty
- Initial $1800.00 · Current $900.00 Reduced
General-duty citation text
29 CFR 1910.134(i)(6): The employer did not ensure that compressors that were not oil-lubricated did not have carbon monoxide levels in the breathing air in excess of 10 parts per million (ppm): a) The employer did not ensure that a carbon monoxide monitor was installed to ensure that the breathing air contained no more than 10 parts per million, on or about 2/2/12.
Recent events (2)
- — I (S) $900
- — Z (S) $1800
1910.157 G04
- Issued
- Penalty
- Initial $1800.00 · Current $900.00 Reduced
General-duty citation text
29 CFR 1910.157(g)(4): Employees who have been designated to use fire fighting equipment as a part of the emergency action plan were not provided training in the use of appropriate equipment upon initial assignment and at least annually thereafter: a) Spray Room: Employer who designated the employee to use fire extinguishers did not provide the spray painter with hands-on-training, or or about 2/2/12.
Recent events (2)
- — I (S) $900
- — Z (S) $1800
1910.304 G05
- Issued
- Penalty
- Initial $1800.00 · Current $900.00 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The paths to ground from circuits, equipment, and enclosures were not permanent, continuous, and effective: a) Spray Room: The plug coming from the pedestal fan did not have a grounding pin, on or about 02/02/2012.
Recent events (2)
- — I (S) $900
- — Z (S) $1800
1910.134 C01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (a) Spray Room: The employer did not develop and implement a written respiratory protection program for the spray painter who was required to wear supplied airline respirator, on or about 2/2/2012.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 811121)
MELROSE, MN—2026-07-16 00:00:00
111612 - GERBER COLLISION MIDWEST DBA GERBER COLLISION - GL
RIPON, WI—2026-07-15 00:00:00
SENECA FOODS CORPORATION
PORTLAND, OR—2026-07-13 00:00:00
317744734 - ATC AUTOBODY & PAINT LLC
SUMMIT, IL—2026-07-08 00:00:00
BUDS BODY SHOP SUPPLY & PAINT
PUYALLUP, WA—2026-07-08 00:00:00
WA317991990 - GLASS WORKS PRO INC
More inspections in NJ
EAST ORANGE, NJ—2026-07-17 00:00:00
EAST ORANGE COMMUNITY CHARTER SCHOOL
EAST ORANGE, NJ—2026-07-17 00:00:00
EAST ORANGE COMMUNITY CHARTER SCHOOL
EAST ORANGE, NJ—2026-07-17 00:00:00
EAST ORANGE COMMUNITY CHARTER SCHOOL
MOUNTAIN LAKES, NJ—2026-07-17 00:00:00
JOHN CARUSO BUILDERS LLC
PENNINGTON, NJ—2026-07-16 00:00:00
BOROUGH OF PENNINGTON DEPARTMENT OF PUBLIC WORKS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332429505.