Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NORTH JERSEY TRUCK CENTER INC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of NORTH JERSEY TRUCK CENTER INC in 236 ROUTE 46 EAST, SADDLE BROOK, NJ 07663 (NAICS 811121). OSHA activity number 332429505.

Watch North Jersey Truck Center INC — free Get an email when a new federal OSHA severe-injury report for North Jersey Truck Center INC is published. One employer, no account, unsubscribe in one click.
Site address
236 ROUTE 46 EAST
City
SADDLE BROOK
State
NJ
ZIP
07663
Mailing
236 ROUTE 46 EAST, SADDLE BROOK, NJ 07663
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811121
Employees
15
Ownership type
A

7 citations on file for this inspection.

1910.107 C06

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2400.00 · Current $1200.00 Reduced
29 CFR 1910.107(c)(6):  Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spray area, and not separated therefrom by partitions, produced sparks under normal operating conditions and did not otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations:    a)  Spray Room:  A pedestal fan was used within approximately 7 feet from the spray area and was not of an explosion proof type for use in a Class I, Division 2 Location, and was used to dry the newly painted surface of truck hoods and parts, on or about 02/02/2012.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2400

1910.107 D06

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $1800.00 · Current $900.00 Reduced
29 CFR 1910.107(d)(6):     Belts entered the duct unless the belt and pulley within the duct or booth are thoroughly enclosed:    a) Spray Room:  The belt and pulley, which were driving the exhaust fan, entered the duct and was not enclosed to prevent them from coming into contact with flammable vapors such as, but not limited to, toluene, xylene, methylethyl ketone, and acetone, on or about  02/02/2011.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1800

1910.107 J02

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $3600.00 · Current $1800.00 Reduced
29 CFR 1910.107(j)(2):  Spray booths, rooms, or other enclosures used for spraying operations was alternately used for the purpose of drying by any arrangement which will cause a material increase in the surface temperature of the spray booth, room, or enclosure.    a)  Spray Room:  The employee, who spray painted truck hood with a solvent that contained class I chemicals such as, but not limited to, toluene, xylene, and acetate, used multiple light bulbs to dry the newly painted surface, on or about 2/2/12.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $3600

1910.134 I06

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1800.00 · Current $900.00 Reduced
29 CFR 1910.134(i)(6):     The employer did not ensure that compressors that were not oil-lubricated did not have carbon monoxide levels in the breathing air in excess of 10 parts per million (ppm):    a)  The employer did not ensure that a carbon monoxide monitor was installed to ensure that the breathing air contained no more than 10 parts per million, on or about 2/2/12.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1800

1910.157 G04

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $1800.00 · Current $900.00 Reduced
29 CFR 1910.157(g)(4):     Employees who have been designated to use fire fighting equipment as a part of the emergency action plan were not provided training in the use of appropriate equipment upon initial assignment and at least annually thereafter:    a)  Spray Room:  Employer who designated the employee to use fire extinguishers did not provide the spray painter with hands-on-training, or or about 2/2/12.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1800

1910.304 G05

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $1800.00 · Current $900.00 Reduced
29 CFR 1910.304(g)(5):     The paths to ground from circuits, equipment, and enclosures were not permanent, continuous, and effective:    a)  Spray Room: The plug coming from the pedestal fan did not have a grounding pin, on or about 02/02/2012.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1800

1910.134 C01

Other-than-serious 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(c)(1):  A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:      (a) Spray Room:  The employer did not develop and implement a written respiratory protection program for the spray painter who was required to wear supplied airline respirator, on or about 2/2/2012.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332429505.