POMPTON PLAINS, NJ —
OSHA Inspection: CHILLER SOLUTIONS LLC
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of CHILLER SOLUTIONS LLC in 101 ALEXANDER AVE, POMPTON PLAINS, NJ 07444 (NAICS 333415). OSHA activity number 332429810.
Where did this inspection happen?
- Establishment
- CHILLER SOLUTIONS LLC
- Site address
- 101 ALEXANDER AVE
- City
- POMPTON PLAINS
- State
- NJ
- ZIP
- 07444
- Mailing
- 101 ALEXANDER AVE, POMPTON PLAINS, NJ 07444
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333415
- Employees
- 11
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.106 D03 II A
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $1320.00 Reduced
General-duty citation text
29 CFR 1910.106(d)(3)(ii)(a): Metal storage cabinets construction. The bottom, top, door, and sides of cabinet were not at least No. 18 gage sheet iron and double walled with 1 1/2 - inch air space. Joints were not riveted, welded or made tight by some equally effective means. The door was not provided with a three-point lock, and the door sill was not raised at least 2 inches above the bottom of the cabinet: a) Spray booth area All flammable liquids were stored in ordinary metal cabinets not designed for flammable materials. Violation observed on or about 02/28/12.
Recent events (2)
- — I (S) $1320
- — Z (S) $2400
1910.107 B09
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $1320.00 Reduced
General-duty citation text
29 CFR 1910.107(b)(9): A clear space of not less than 3 feet on all sides was not kept free from storage or combustible construction: a) Spray booth area A clear space of not less than three feet was not kept free of storage of combustible and other materials. Items such as, but not limited to, a cart, wooden pallet and plywood were placed immediately next to the spray booth. Violation observed on or about 02/28/12.
Recent events (2)
- — I (S) $1320
- — Z (S) $2400
1910.107 C06
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $1320.00 Reduced
General-duty citation text
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations: a) Spray booth area The light fixture approximately 10 feet above the spray booth was not explosion-proof type approved for Class 1 Division 1 hazardous locations. Flammable paints are sprayed inside the spray booth. Violation observed on or about 02/28/12.
Recent events (2)
- — I (S) $1320
- — Z (S) $2400
1910.107 C07
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.107(c)(7): Electric lamps outside of but within 20 feet of spraying area(s), and not separated therefrom by partition(s), were not totally enclosed to prevent the falling of hot particles: a) Spray booth area The light fixture approximately 10 feet above the spray booth was not totally enclosed to prevent falling of hot particles. Violation observed on or about 02/28/12.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 G02
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $1320.00 Reduced
General-duty citation text
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary: a) Spray Booth The inside of the spray booth was not kept free from accumulation of paint residue. Violation observed on or about 02/28/12.
Recent events (2)
- — I (S) $1320
- — Z (S) $2400
1910.134 C01
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $1320.00 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not implemented for required respirator use: a) Facility The employer did not implement the written respiratory protection program for an employee required to wear an elastomeric half mask, negative pressure respirator while handling hazardous materials such as, but not limited to, A-Side DP-BP Handmix which contains diphenylmethane-4.4'-diisocyanate (MDI). Violation disclosed on or about 03/06/12.
Recent events (2)
- — I (S) $1320
- — Z (S) $2400
1910.134 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) Facility The employer did not provide a medical evaluation to an employee required to wear an elastomeric half mask, negative pressure respirator while handling hazardous chemicals such as, but not limited to, A-Side DP-BP Handmix which contains diphenylmethane-4.4'-diisocyanate (MDI). Violation disclosed on or about 03/06/12.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.138 A
- Issued
- Abate by
- Penalty
- Initial $1800.00 · Current $990.00 Reduced
General-duty citation text
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes: a) Facility The employer did not select appropriate hand protection when employees' hands were exposed to skin absorption of harmful substances such as, but not limited to, A-Side DP-BP Handmix (which contains diphenylmethane-4.4'-diisocyanate) and B-Side 9900-2 Handmix (which contains Polyol). Violation observed on or about 03/06/12.
Recent events (2)
- — I (S) $990
- — Z (S) $1800
1910.305 B02 I
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $1320.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers identified for the purpose: a) Spray booth area The junction box across from the spray booth was not provided with a cover exposing employees to a fire hazard due to the spraying of flammable paint. Violation observed on or about 02/28/12.
Recent events (2)
- — I (S) $1320
- — Z (S) $2400
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $4800.00 · Current $2640.00 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communicationprogram which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning,material safety data sheets, and employee information and training will be met, and which also includes the following: a) Facility The employer did not implement the written hazard communication program for employees required to use hazardous materials such as, but not limited to, A-Side DP-BP Handmix which contains diphenylmethane-4.4'-diisocyanate (MDI). Employees were not provided effective information and training. Violation disclosed on or about 03/01/12. Chiller Solutions LLC was previously cited for a violation of this Occupational Safety and Health standard or its equivalent 29 CFR 1910.1200(e)(1) which was contained in OSHA Inspection Number 315438770, Citation Number 1, Item Number 3A, which became a Final Order on 05/10/11.
Recent events (2)
- — I (R) $2640
- — Z (R) $4800
1910.1200 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) Facility The employer did not provide effective information and training for employees required to use hazardous chemicals such as, but not limited to, A-Side DP-BP Handmix which contains diphenylmethane-4.4'-diisocyanate (MDI). Violation disclosed on or about 03/01/12. Chiller Solutions LLC was previously cited for a violation of this Occupational Safety and Health standard or its equivalent 29 CFR 1910.1200(h)(1) which was contained in OSHA Inspection Number 315438770, Citation Number 1, Item Number 3B, which became a Final Order on 05/10/11.
Recent events (2)
- — I (R) $0
- — Z (R) $0
More inspections at CHILLER SOLUTIONS LLC
POMPTON PLAINS, NJ—2011-03-21 00:00:00
CHILLER SOLUTIONS LLC
POMPTON PLAINS, NJ—2005-07-14 00:00:00
CHILLER SOLUTIONS, LLC
POMPTON PLAINS, NJ—2005-07-12 00:00:00
CHILLER SOLUTIONS, LLC
View CHILLER SOLUTIONS LLC's full OSHA safety record →
More inspections in this industry (NAICS 333415)
RICHMOND, VA—2026-07-13 00:00:00
CONDAIR OPERATIONS, LLC
BROKEN ARROW, OK—2026-07-10 00:00:00
AMERICAN WHEATLEY
LAUREL, MS—2026-07-01 00:00:00
THERMO-KOOL
OSSEO, WI—2026-07-01 00:00:00
TITAN AIR, LLLP
OSSEO, WI—2026-06-22 00:00:00
TITAN AIR, LLLP
More inspections in NJ
PERTH AMBOY, NJ—2026-07-16 00:00:00
ENGLERT INC.
RIDGEFIELD, NJ—2026-07-16 00:00:00
COLORITE PLASTICS COMPANY
BERLIN, NJ—2026-07-16 00:00:00
URUS CONSTRUCTION CORPORATION
GLASSBORO, NJ—2026-07-15 00:00:00
GLASSBORO WATER & SEWER DEPARTMENT
FLANDERS, NJ—2026-07-15 00:00:00
TRI-STATE QUIKRETE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332429810.