MERIDIAN, ID —
OSHA Inspection: DOUBLE J FRAMING, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DOUBLE J FRAMING, LLC in 3630 N. EAGLE ROAD, MERIDIAN, ID 83646 (NAICS 238130). OSHA activity number 332791862.
Where did this inspection happen?
- Establishment
- DOUBLE J FRAMING, LLC
- Site address
- 3630 N. EAGLE ROAD
- City
- MERIDIAN
- State
- ID
- ZIP
- 83646
- Mailing
- 3112 SUNTREE STREET, CALDWELL, ID 83605
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 6
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.501 B01
- Issued
- Penalty
- Initial $2040.00 · Current $1020.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) East end to center area of the structure; On or about February 27, 2012 and at times prior thereto, an employee was performing roof sheathing without a means of fall protection. b) West end to center area of the structure; On or about February 27, 2012 and at times prior thereto, three employees walked across the tops of trusses between the location of the ladder and the sheathed area without a means of fall protection. Note: Abatement certification is NOT required for this item.
Recent events (2)
- — I (S) $1020
- — Z (S) $2040
1926.28 A
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.28(a): Appropriate personal protective equipment was not worn by employee(s) in all operations where there was exposure to hazardous conditions: a) Staging area at the south side of the structure; On or about February 27, 2012 and at times prior thereto, an employee was cutting material operating a 12 inch DeWalt compound miter saw without eye/face protection. Note: Abatement certification is NOT required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.302 A02
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.302(a)(2): The use of electric cords for hoisting or lowering tools was permitted: a) South side facade of the structure; On or about February 27, 2012 and at times prior thereto, an employee utilized the combination of an extension cord and the power cord for a Milwaukee 7 1/4 inch worm drive circular saw to lower it from the roof deck to the ground. Note: Abatement certification is NOT required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.502 D06 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
1926.502(d)(6)(i): The snaphook was not designed to be engaged directly to webbing, rope or wire rope: a) West end, center area of truss span; On or about February 27, 2012 and at times prior thereto, two separate horizontal rope lifelines were wrapped around truss members and the snaphooks were connected to the rope lifeline in lieu of being connected to a fall protection anchoring device. Note: Abatement certification is NOT required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at DOUBLE J FRAMING, LLC
NAMPA, ID—2022-05-06 00:00:00
DOUBLE J FRAMING, LLC
BEND, OR—2013-12-30 00:00:00
DOUBLE J FRAMING LLC
BEND, OR—2013-11-13 00:00:00
DOUBLE J FRAMING LLC
GARDEN CITY, ID—2012-07-26 00:00:00
DOUBLE J FRAMING, LLC
View DOUBLE J FRAMING, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238130)
ENCINITAS, CA—2026-07-13
LOU RIDDLE CONSTRUCTION
MERIDIAN, ID—2026-07-10
IDAHO HOMES CONSTRUCTION LLC
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
METTER, GA—2026-07-10
M.A.P.C CONSTRUCTION, LLC
SLINGER, WI—2026-07-10
RAMIREZ HOME BUILDERS LLC
More inspections in ID
GOODING, ID—2026-07-10
DAHLGREN INDUSTRIAL INC.
MERIDIAN, ID—2026-07-10
IDAHO HOMES CONSTRUCTION LLC
MERIDIAN, ID—2026-07-10
DIAMOND CONCRETE, LLC
BOISE, ID—2026-07-09
POWERHOUSE ELECTRIC INC.
BOISE, ID—2026-07-09
MARK GUHO CONSTRUCTION COMPANY
Source