OSHA Inspection: NORTHFORK BUILDERS INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of NORTHFORK BUILDERS INC. in 48775 S LAKE OWEN DR, CABLE, WI 54821 (NAICS 236115). OSHA activity number 332812056.

Watch Northfork Builders INC. — free Get an email when a new federal OSHA severe-injury report for Northfork Builders INC. is published. One employer, no account, unsubscribe in one click.
Site address
48775 S LAKE OWEN DR
City
CABLE
State
WI
ZIP
54821
Mailing
43210 KAVANAUGH RD PO BOX 74, CABLE, WI 54821
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
10
Ownership type
A

7 citations on file for this inspection.

1926.304 H01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1960.00 Reduced
29 CFR 1926.304(h)(1): Each circular crosscut table saw was not guarded by a hood which met all the requirements of paragraph (i)(1) of this section for hoods for circular ripsaws:  a) At 48775 S Lake Owen Drive in Cable, WI in the garage; The employees were exposed to hazards as the Powermatic table saw did not have an adequate hood guard.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1926.403 B02

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $3430.00 Reduced
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:  a) At 48775 S Lake Owen Drive in Cable, WI in the storage area attached to the garage; The portable heater unit was not listed or approved for use in the manner that it was used by a recognized underwriter laboratory.
Recent events (2)
  • — I (S) $3430
  • — Z (S) $4900

1926.407 B

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.407(b): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not approved as intrinsically safe or approved for the hazardous (classified) location or safe for the hazardous (classified) location:  a) At 48775 S Lake Owen Drive in Cable, WI in the storage area attached to the garage; The heater unit was not approved as intrinsically safe for a Class I location.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.405 B02

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1960.00 Reduced
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy:  a) At 48775 S Lake Owen Drive in Cable, WI in the garage and the family cabin; The employees were exposed to hazards when working near energized outlet boxes that did not have faceplates.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1926.405 J01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(j)(1)(i): Fixtures, lampholders, lamps, rosettes, or receptacles had live parts normally exposed to employee contact:  a) At 48775 S Lake Owen Drive in Cable, WI in the garage; The employees were exposed to hazards as the energized light switches did not have cover plates on them.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B01

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $0.00 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface having an unprotected side or edge which was six or more feet (1.8m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:  a) At 48775 S Lake Owen Drive in Cable, WI in the family cabin; The employees were exposed to hazards while accessing the unguarded loft area without the use of fall protection.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2800

1926.1052 C01 II

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $1400.00
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever was less, were not equipped with one stairrail system along each unprotected side or edge:  a) At 48775 S Lake Owen Drive in Cable, WI in the family cabin; The employees were exposed to hazards as they accessed the stairwell going up to the 2nd level and down into the basement. The stairwells did not have a handrails on the open sides.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332812056.