Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: METAL FINISHING RESEARCH

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of METAL FINISHING RESEARCH in 4025 S. PRINCETON AVE, CHICAGO, IL 60609 (NAICS 325510). OSHA activity number 332821172.

Watch Metal Finishing Research — free Get an email when a new federal OSHA severe-injury report for Metal Finishing Research is published. One employer, no account, unsubscribe in one click.
Site address
4025 S. PRINCETON AVE
City
CHICAGO
State
IL
ZIP
60609
Mailing
4025 S. PRINCETON AVE, CHICAGO, IL 60609
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Case closed
Last modified
Data loaded
NAICS code
325510
Employees
14
Ownership type
A

5 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 2 exposed
Issued
Abate by
Penalty
Initial $2550.00 · Current $1275.00 Reduced
29 CFR 1910.23(c)(1):     Open-sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides:    1) Powder Room- On or about 03/20/12, employees were required to work from a platform at a height of 8 feet without a standard guard railing system or equivalent. Employees were thereby exposed to the hazards associated with falls.
Recent events (2)
  • — I (S) $1275
  • — Z (S) $2550

1910.23 D01 III

Serious Gravity 5 2 exposed
Issued
Abate by
Penalty
Initial $2040.00 · Current $1020.00 Reduced
29 CFR 1910.23(d)(1)(iii):     Stairway(s) less than 44 inches wide having both sides open, did not have one stair railing on each side:    1) Powder Room- On or about 03/20/12, employees were required to use unprotected (no mid-rails) platform stairs when mixing product. Employees were thereby exposed to the hazards associated with falls.       2) Liquid Room- On or about 03/20/12, employees were required to use unprotected (no mid-rails) platform stairs when mixing product. Employees were thereby exposed to the hazards associated with falls.    3) Bulk Storage Area- On or about 03/20/12, employees were required to use unprotected (no mid-rails) platform stairs when maintaining and servicing bulk storage tanks. Employees were thereby exposed to the hazards associated with falls.
Recent events (2)
  • — I (S) $1020
  • — Z (S) $2040

1910.147 C01

Serious Gravity 5 1 exposed
Issued
Abate by
Penalty
Initial $2550.00 · Current $1275.00 Reduced
29 CFR 1910.147(c)(1):     The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    1) Metal Finishing Research- On or about 03/20/12, the employer did not establish an energy control (lockout/tagout) program which includes energy control procedures, employee training and periodic inspections to ensure employees performing servicing or maintenance on machinery or equipment, such as the Liquid and Powder mixing machines.
Recent events (2)
  • — I (S) $1275
  • — Z (S) $2550

1910.212 A01

Serious Gravity 5 2 exposed
Issued
Abate by
Penalty
Initial $2550.00 · Current $1275.00 Reduced
29 CFR 1910.212(a)(1):     One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    1) Powder Room- On or about 03/20/12, the employer failed to provide adequate guarding for rotating parts of the mixing machines. Employees were exposed to coming in contact with the rotating blades.     2) Liquid Room- On or about 03/20/12, the employer failed to provide a guard for the rotating parts of a mixing machine. Employees were exposed to coming in contact with the rotating blades.
Recent events (2)
  • — I (S) $1275
  • — Z (S) $2550

1910.24 B

Deleted Other-than-serious 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.24(b):     Spiral stairway(s) were used where it was pratical to provide a conventional stairway:    1) Liquid Room- On or about 03/20/12, employees were required to use a spiral stairway to move from the mixing platform to the ground floor. Employees were thereby exposed to the hazards associated with falls.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View METAL FINISHING RESEARCH's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332821172.