OSHA Inspection: DIMENSIONAL CONTRACTORS, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DIMENSIONAL CONTRACTORS, LLC in 6816 ALGONQUIN DR., MIDDLETON, WI 53562 (NAICS 236118). OSHA activity number 332822097.

Watch Dimensional Contractors, LLC — free Get an email when a new federal OSHA severe-injury report for Dimensional Contractors, LLC is published. One employer, no account, unsubscribe in one click.
Site address
6816 ALGONQUIN DR.
City
MIDDLETON
State
WI
ZIP
53562
Mailing
6621 W. LINCOLN AVE., WEST ALLIS, WI 53022
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
8
Ownership type
A

3 citations on file for this inspection.

1903.19 D01

Other-than-serious 2 instances 8 exposed
Issued
Abate by
Penalty
Initial $600.00 · Current $600.00
29 CFR 1903.19(d)(1):  The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required.    The employer did not submit documentation regarding teh abatement of teh following cited hazards:    a.  Eye protection not worn while using a pneumatice nail gun to install roofing shingles.    b.  Employees installing roofing shingles were not protected from falls.
Recent events (1)
  • — Z (O) $600

1926.102 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3600.00 · Current $1000.00 Reduced
29 CFR 1926.102(a)(1): Employees shall be provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents.                              Employees were not provided with safety glasses while using a pnuematic nail gun to install shingles on a roof.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $3600

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4200.00 · Current $1400.00 Reduced
29 CFR 1926.501(b)(13):  "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.  Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.                Employees installing shingles on a residential roof were not protected from falling to lower levels.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $4200