Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: PETROLEUM PRODUCTS & SERVICES, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PETROLEUM PRODUCTS & SERVICES, INC in 11633 SPRING CYPRESS, TOMBALL, TX 77377 (NAICS 333132). OSHA activity number 333290187.

Watch Petroleum Products & Services, INC — free Get an email when a new federal OSHA severe-injury report for Petroleum Products & Services, INC is published. One employer, no account, unsubscribe in one click.
Site address
11633 SPRING CYPRESS
City
TOMBALL
State
TX
ZIP
77377
Mailing
11633 SPRING CYPRESS, TOMBALL, TX 77377
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333132
Employees
31
Ownership type
A

2 citations on file for this inspection.

1910.212 A01

Serious Gravity 10 6 instances 4 exposed
Issued
Abate by
Penalty
Initial $4200.00 · Current $2520.00 Reduced
29 CFR 1910.212(a)(1):     Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by:  point of operations and rotating parts and/or flying chips or sparks.     The employer does not ensure that CNC machines with interlocks are working in the safe operation. This violation occured and was observed at worksite located at 11633 Spring Cypress, Tomball, Texas on or about March 19, 2012, and times prior thereto, where employees, who were operating the following Vertical Lathes without working interlocks and CNC Lathes without chuck guards:    Vertical Lathes   1) Yang SMV1000 #106,    2) Okuma #105   3) Okuma LC40   4) Okuma #104    CNC Lathes w/o Chuck guards    5) Kingston HD30 #111  6) Summit Lathe #112
Recent events (2)
  • — I (S) $2520
  • — Z (S) $4200

1910.147 C01

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $2940.00 Reduced
29 CFR 1910.147(c)(1):     The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    In manufacuturing faciility; the employer did not develop or implement an energy control program where employees are exposed to electrical and pneumatic energy devices.      This violatoin was observed on or about 3/19/2012 in the manufacturing facility where employees are conducting servicing and maintenance activities on the following 3-phase voltage equipment with, but not limited to, electrical and pneumatic energy devices. this condition exposed employee to struck-by hazards and caught-in hazards.     1) Cincinnati Milacron, 480 Volts, Pnuematic  2) Honeoye, 220 Volts  3) Webb 2VH, 220 Volts  4) Sumith Lathe, #112,  220 Volts,   5) Kingstone HD 30 Lathe, #111, 440 Volts  6) Mazak Powercenter, 208 Volts, Pneumatic  7) Yang SMV1000, #106, 208 Volts, 45 - 4000 RPM,  Pneumatic  8) Bullard, 480 Votls  9) Ikeda Drill, 480 volts  10) Okuma LC40, #105, 208 Volts  11) Okuma LH55, #104. 208 Volts  13) Okuma #103, 208 Volts  12) Puma 12, 208 Volts  13) Puma 700, 208 volts  14) Mazak 400, 460 volts, Pneumatic  15) Mazak 1060V, #100, 460 volts, Pneumatic
Recent events (2)
  • — I (S) $2940
  • — Z (S) $4900

RNWBL