OSHA Inspection: LANTERN DRILLING COMPANY, RIG #10

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LANTERN DRILLING COMPANY, RIG #10 in FILLINGIM 02-55H, HEMPHILL COUNTY, 13 MILES SE OF CANADIAN, CANADIAN, TX 79014 (NAICS 211111). OSHA activity number 333865020.

Watch Lantern Drilling Company, RIG #10 — free Get an email when a new federal OSHA severe-injury report for Lantern Drilling Company, RIG #10 is published. One employer, no account, unsubscribe in one click.
Site address
FILLINGIM 02-55H, HEMPHILL COUNTY, 13 MILES SE OF CANADIAN
City
CANADIAN
State
TX
ZIP
79014
Mailing
8601 N. CR W, ODESSA, TX 79764
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
211111
Employees
24
Ownership type
A

7 citations on file for this inspection.

1910.151 C

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $3400.00 · Current $2380.00 Reduced
29 CFR 1910.151(c):     Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:      On or about April 10, 2012, employees were exposed to chemical hazards in that the employer had not installed a shower for employees in the chemical mixing area.
Recent events (2)
  • — I (S) $2380
  • — Z (S) $3400

1910.157 C01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2550.00 · Current $1785.00 Reduced
29 CFR 1910.157(c)(1):     The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.      On or about April 10, 2012, employees were exposed to fire hazards in that the employer did ensure that a portable fire extinguisher was mounted in the engine oil and hydraulic fluid area.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $2550

1910.178 Q01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $3400.00 · Current $2380.00 Reduced
29 CFR 1910.178(q)(1):     Any power-operated industrial truck not in safe operating condition was not removed from service. All repairs were not made by authorized personnel.      On about April 10, 2012, employees were exposed to struck by hazards in that the employer did not ensure that the Skytrak forklift had a working back up alarm.
Recent events (2)
  • — I (S) $2380
  • — Z (S) $3400

1910.253 B02 II

Deleted Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2550.00 · Current $0.00 Reduced
29 CFR 1910.253(b)(2)(ii):     Inside of buildings, cylinders was not stored in a well-protected, well-ventilated, dry location, at least 20 (6.1 m) feet from highly combustible materials such as oil or excelsior. Cylinders should be stored in definitely assigned places away from elevators, stairs, or gangways. Assigned storage spaces was not located where cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. Cylinders was not kept in unventilated enclosures such as lockers and cupboards.      On or about April 10, 2012, employees were exposed to struck-by hazards in that the employer did not ensure that an oxygen cylinder was secured.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2550

1910.303 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3400.00 · Current $2380.00 Reduced
29 CFR 1910.303(b)(2):     Installation and use. Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing or labeling.    On or about April 10, 2012, an electrical junction box was being used with the conductors on the outside on the north wall in the driller cabin exposing employees to electric hazards.
Recent events (2)
  • — I (S) $2380
  • — Z (S) $3400

1910.304 G05

Serious Gravity 5 3 instances 5 exposed
Issued
Abate by
Penalty
Initial $3400.00 · Current $2380.00 Reduced
29 CFR 1910.304(g)(5):     Grounding path. The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective.      On or about April 10, 2012, employees were exposed to electric hazards in that the employer did not ensure that equipment was effectively grounded.         a) The electrical equipment, "Danger High Voltage.       b) The generator for the rig.       c)  Pump connected to the five water containers.
Recent events (2)
  • — I (S) $2380
  • — Z (S) $3400

1910.305 B02 I

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $3400.00 · Current $2380.00 Reduced
29 CFR 1910.305(b)(2)(i):     All pull boxes, junction boxes, and fittings were not provided with covers identified for the purpose. If metal covers are used, they were not grounded. In completed installations, each outlet box did not have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass did not provide bushings designed for the purpose or did not have smooth, well-rounded surfaces on which the cords may bear.      On or about April 10, 2012, employees were exposed to electric haxards in that the employer that did not ensure that a light swith in the bathroom had a face plate.
Recent events (2)
  • — I (S) $2380
  • — Z (S) $3400

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 333865020.