2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: POWERLAB, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of POWERLAB, INC. in 9741 POWERLAB RD., SAVANNA, IL 61074 (NAICS 325188). OSHA activity number 334032430.

Watch Powerlab, INC. — free Get an email when a new federal OSHA severe-injury report for Powerlab, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
POWERLAB, INC.
Site address
9741 POWERLAB RD.
City
SAVANNA
State
IL
ZIP
61074
Mailing
P.O. BOX 308, SAVANNA, IL 61074
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325188
Employees
11
Ownership type
A

2 citations on file for this inspection.

1910.1025 E04 I

Deleted Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1320.00 · Current $0.00 Reduced

Hazardous substances 1591

29 CFR 1910.1025(e)(4)(i):     When ventilation was used to control exposure to lead, measurements which demonstrate the effectiveness of they system in controlling exposure were not made at least every three months:    Facility: The employer did not conduct ventilation measurements such as capture velocity, duct velocity, or static pressure to determine the exhaust system effectiveness at least every three month.    Abatement documentation is required for this item in accordance with the     requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $0
  • — Z (S) $1320

1910.1025 H01

Deleted Repeat Gravity 5 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $4400.00 · Current $0.00 Reduced

Hazardous substances 1591

29 CFR 1910.1025(h)(1):     All surfaces were not maintained as free as practicable of accumulations of lead:    Break Room: Break room wipe samples revealed lead residue on the following surfaces:       1. 10mg of lead on microwave handle        2. 19mg of lead on table       3.15mg of lead on refrigerator handle    The Powerlab, Inc. was previously cited for a violation of this Occupational Safety and Health Standard or its equivalent standard, 29 CFR 1910.1025 (h) (1), which was contained in OSHA Inspection Number 314034166, Citation Number 1, Item Number 3 and was affirmed as a final order on issued 06/07/2010, with respect to a workplace location at 9741 Powerlab Road, Savanna, IL    Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (R) $0
  • — Z (R) $4400

View POWERLAB, INC.'s full OSHA safety record →