2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: POWERLAB, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of POWERLAB, INC. in 9741 POWERLAB RD., SAVANNA, IL 61074 (NAICS 325180). OSHA activity number 347355646.

Watch Powerlab, INC. — free Get an email when a new federal OSHA severe-injury report for Powerlab, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
POWERLAB, INC.
Site address
9741 POWERLAB RD.
City
SAVANNA
State
IL
ZIP
61074
Mailing
P.O. BOX 913, TERRELL, TX 75160
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325180
Employees
15
Ownership type
A

1 citation on file for this inspection.

1910.134 H01

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $6452.00 · Current $0.00 Reduced

Hazardous substances 1591

29 CFR  1910.134(h)(1): Cleaning and disinfecting. The employer shall provide each respirator user with a respirator that is clean, sanitary, and in good working order. The employer failed to ensure that respirators are cleaned and disinfected using the procedures in Appendix B-2 of this section, or procedures recommended by the respirator manufacturer, provided that such procedures are of equivalent effectiveness. The respirators shall be cleaned and disinfected at the following intervals:  On or about March 19, 2024, the employer failed to ensure employees working in close proximity to lead while manufacturing lead ingots were properly cleaning their respirator, resulting in lead exposures. A wipe sample taken from the inside of a foreman's powered air-purifying respirator showed an exposure of 126.8024 micrograms of lead.  Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $0
  • — Z (S) $6452

View POWERLAB, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347355646.