LYNDHURST, NJ —
OSHA Inspection: MICHAEL J. MALPERE COMPANY INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MICHAEL J. MALPERE COMPANY INC. in 281 STUYVESTANT AVENUE, LYNDHURST, NJ 07071 (NAICS 238140). OSHA activity number 334092442.
Where did this inspection happen?
- Establishment
- MICHAEL J. MALPERE COMPANY INC.
- Site address
- 281 STUYVESTANT AVENUE
- City
- LYNDHURST
- State
- NJ
- ZIP
- 07071
- Mailing
- PO BOX 187, 8 MANSION TERRACE, CRANFORD, NJ 07016
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 9
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.416 A01
- Issued
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means: a) Roof: The scaffold power supply cords were located inside of the electric cabinet. Workers accessed the electric cabinet that contained exposed energized electric parts, on or about 4/27/2012.
Recent events (1)
- — Z (S) $2000
1926.451 G03 I
- Issued
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.451(g)(3)(i): Verical lifelines used were not protected from sharp edges and abrasion: a) Roof Parapet: The lifelines used by the workers on the suspension scaffolds were not protected, on or about 4/27/2012.
Recent events (1)
- — Z (S) $2000
1926.502 D15
- Issued
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached: a) Roof Area: Multiple fall arrest system lifelines, used by the workers on the two-point suspension scaffolds, were attached to the same anchor point bracket, on or about 4/27/2012.
Recent events (1)
- — Z (S) $2000
More inspections in this industry (NAICS 238140)
RENO, NV—2026-07-16 00:00:00
DC MASONRY
WINNETKA, IL—2026-07-15 00:00:00
CHICAGO STUCCO CO.
WINNETKA, IL—2026-07-15 00:00:00
CHICAGO STUCCO CO.
LODI, NJ—2026-07-15 00:00:00
J & O MASONRY CONTRACTORS
DORAVILLE, GA—2026-07-14 00:00:00
SUDLOW CONCRETE, INC.
More inspections in NJ
EAST ORANGE, NJ—2026-07-17 00:00:00
EAST ORANGE COMMUNITY CHARTER SCHOOL
EAST ORANGE, NJ—2026-07-17 00:00:00
EAST ORANGE COMMUNITY CHARTER SCHOOL
EAST ORANGE, NJ—2026-07-17 00:00:00
EAST ORANGE COMMUNITY CHARTER SCHOOL
MOUNTAIN LAKES, NJ—2026-07-17 00:00:00
JOHN CARUSO BUILDERS LLC
PENNINGTON, NJ—2026-07-16 00:00:00
BOROUGH OF PENNINGTON DEPARTMENT OF PUBLIC WORKS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334092442.