Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PERFORMANCE ELECTRICAL SOLUTIONS INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PERFORMANCE ELECTRICAL SOLUTIONS INC. in 8131 HAUSMAN RD, SAN ANTONIO, TX 78249 (NAICS 238210). OSHA activity number 334109022.

Watch Performance Electrical Solutions INC. — free Get an email when a new federal OSHA severe-injury report for Performance Electrical Solutions INC. is published. One employer, no account, unsubscribe in one click.
Site address
8131 HAUSMAN RD
City
SAN ANTONIO
State
TX
ZIP
78249
Mailing
1001 N FLORES ST STE 2, SAN ANTONIO, TX 78212
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.51 A01

Serious Gravity 10 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1926.51(a)(1): An adequate supply of potable water was not provided in all places of employment.    a) On May 01, 2012, and at times prior thereto at this construction site, potable water was not provided to employees.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.405 B01

Serious Gravity 5 1 exposed
Issued
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.405(b)(1): Unused openings in cabinets, boxes, and fittings were not effectively closed:    a) On May 01 2012, and at times prior thereto at this job site, the temporary power source located on the west side of the construction building, had an unused opening on the underside of the temporary electrical distribution panel that was not effectively closed.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

View PERFORMANCE ELECTRICAL SOLUTIONS INC.'s full OSHA safety record →