Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: DISCOUNT PLUMBING INCORPORATED

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of DISCOUNT PLUMBING INCORPORATED in 7322 W 61ST ST, SUMMIT, IL 60501 (NAICS 238220). OSHA activity number 334122223.

Watch Discount Plumbing Incorporated — free Get an email when a new federal OSHA severe-injury report for Discount Plumbing Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
7322 W 61ST ST
City
SUMMIT
State
IL
ZIP
60501
Mailing
2421 W. PRATT BLVD. #810, CHICAGO, IL 60645
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
10
Ownership type
A

6 citations on file for this inspection.

1926.101 C

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1320.00 · Current $1320.00
29 CFR 1926.101(c): Plain cotton is not an acceptable protective device.    a.  On or about May 2, 2012, at the above addressed jobsite, an employee using an electric jackhammer used cotton balls for hearing protection, thereby exposing the employee to the hazards associated with noise.
Recent events (1)
  • — Z (S) $1320

1926.102 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.102(a)(1):  Employees shall be provided with eye and face protection equipment when machines or operationspresent potential eye or face injury from physical, chemical, or radiation agents.    a.  On or about May 2, 2012, at the above addressed jobsite, an employee using an electric jackhammer did not wear safety glasses, thereby exposing the employee to the hazards associated with eye injuries.
Recent events (1)
  • — Z (S) $0

1926.403 I02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1760.00 · Current $1760.00
29 CFR 1926.403(i)(2)(i): Except as required or permitted elsewhere in this subpart, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by cabinets or other forms of enclosures, or by any of the followingmeans:    a.  On or about May 2, 2012 - at the above addressed jobsite, an employee using an electric jackhammer on the ground floor was working around, and/or using electrical outlets that were not provided with covers or face plates to protect against accidental contact, thereby exposing the employee to electrical hazards.
Recent events (1)
  • — Z (S) $1760

1926.405 A02 II B

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(a)(2)(ii)(B): Branch circuits shall originate in a power outlet or panelboard. Conductors shall be run as multiconductor cord or cable assemblies or open conductors, or shall be run in raceways. All conductors shall be protected by overcurrent devices attheir ampacity. Runs of open conductors shall be located where the conductors will not be subject to physical damage, and the conductors shall befastened at intervals not exceeding 10 feet (3.05 m). No branch-circuit conductors shall be laid on the floor. Each branch circuit that suppliesreceptacles or fixed equipment shall contain a separate equipment grounding conductor if the branch circuit is run as open conductors.    a.  On or about May 2, 2012 - at the above addressed jobsite, an employee using an electric jackhammer was working around conductors that were not protected from physical damage, thereby exposing the employee to electric shocks.
Recent events (1)
  • — Z (S) $0

1926.405 A02 II E

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(a)(2)(ii)(E): All lamps for general illumination shall be protected from accidental contact or breakage.Metal-case sockets shall be grounded.    a.  On or about May 2, 2012 - at the above addressed jobsite, an employee using an electric jackhammer on the ground floor, was exposed to electrical hazards due to temporary lighting not being protected from accidental contact or breakage, thereby exposing the employee to hazards associated with electrical shock.
Recent events (1)
  • — Z (S) $0

1926.404 B01 I

Repeat Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4400.00 · Current $4400.00
29 CFR 1926.404(b)(1)(i): General. The employer shall use either ground fault circuit interrupters as specified inparagraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section toprotect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.    On or about May 2, 2012 - at the above addressed jobsite, receptacles used as part of a temporary electrical system were not protected by ground fault circuit interrupters or an assured equipment grounding program, thereby exposing the employee to hazards associated with electrical shock.    THE DISCOUNT PLUMBING INCORPORATED WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 1926.404(b)(1)(i), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 312752157, CITATION NUMBER 1, ITEM NUMBER 2 AND WAS AFFIRMED AS A FINAL ORDER ON JANUARY 22, 2009 WITH RESPECT TO A WORKPLACE LOCATED AT 7240 W. DEVON AVE, CHICAGO, IL 60618.
Recent events (1)
  • — Z (R) $4400

View DISCOUNT PLUMBING INCORPORATED's full OSHA safety record →