Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ROCKERZ, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ROCKERZ, INC. in 102 SOUTH 3RD STREET, WOMELSDORF, PA 19567 (NAICS 238330). OSHA activity number 334230430.

Watch Rockerz, INC. — free Get an email when a new federal OSHA severe-injury report for Rockerz, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ROCKERZ, INC.
Site address
102 SOUTH 3RD STREET
City
WOMELSDORF
State
PA
ZIP
19567
Mailing
100 COMMONWEALTH DRIVE, WARRENDALE, PA 15086
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238330
Employees
2
Ownership type
A

2 citations on file for this inspection.

1926.405 G02 III

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2800.00 · Current $1540.00 Reduced
29 CFR 1926.405(g)(2)(iii): Flexible cords were not used only in continuous lengths without splice or tap.     (a) Construction Site, Hallway - On or about May 9th 2012 employees were using a wet dry vacuum and grinder for edging floor corners and were exposed to electrical shocks from the energized 110 volt spliced flexible cord.    No abatement certification or documentation required.
Recent events (2)
  • — I (S) $1540
  • — Z (S) $2800

1926.404 B01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.404(b)(1)(i): The employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites.    (a) Construction Site, Hallway - On or about May 9th, 2012 employees were using a wet dry vacuum and grinder for edging floor corners and were exposed to electrical shocks while the 110 volt equipment was not connected to a ground fault circuit interrupter.     No abatement certification or documentation required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View ROCKERZ, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334230430.