WOMELSDORF, PA —
OSHA Inspection: ROCKERZ, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ROCKERZ, INC. in 102 SOUTH 3RD STREET, WOMELSDORF, PA 19567 (NAICS 238330). OSHA activity number 334230430.
Where did this inspection happen?
- Establishment
- ROCKERZ, INC.
- Site address
- 102 SOUTH 3RD STREET
- City
- WOMELSDORF
- State
- PA
- ZIP
- 19567
- Mailing
- 100 COMMONWEALTH DRIVE, WARRENDALE, PA 15086
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238330
- Employees
- 2
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.405 G02 III
- Issued
- Penalty
- Initial $2800.00 · Current $1540.00 Reduced
General-duty citation text
29 CFR 1926.405(g)(2)(iii): Flexible cords were not used only in continuous lengths without splice or tap. (a) Construction Site, Hallway - On or about May 9th 2012 employees were using a wet dry vacuum and grinder for edging floor corners and were exposed to electrical shocks from the energized 110 volt spliced flexible cord. No abatement certification or documentation required.
Recent events (2)
- — I (S) $1540
- — Z (S) $2800
1926.404 B01 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.404(b)(1)(i): The employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. (a) Construction Site, Hallway - On or about May 9th, 2012 employees were using a wet dry vacuum and grinder for edging floor corners and were exposed to electrical shocks while the 110 volt equipment was not connected to a ground fault circuit interrupter. No abatement certification or documentation required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at ROCKERZ, INC.
DEARBORN, MI—2015-03-09 00:00:00
ROCKERZ, INC.
MONROEVILLE, PA—2003-06-26 00:00:00
ROCKERZ INC.
WASHINGTON, PA—2003-05-16 00:00:00
ROCKERZ INC.
View ROCKERZ, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238330)
WEST HARTFRD, CT—2026-07-02 00:00:00
NEXT LEVEL CONCRETE COATING LIMITED LIABILITY COMPANY
RICHLAND, WA—2026-06-24 00:00:00
WA317991783 - VM CARPET INSTALLATION LLC
WASHINGTON, PA—2026-06-18 00:00:00
CREATIVE FLOOR SOLUTIONS
LEBANON, TN—2026-06-17 00:00:00
MARIA L. CHACON ORELLANA
EVELETH, MN—2026-06-15 00:00:00
111427 - CONTRACT TILE AND CARPET LLC
More inspections in PA
COLUMBIA, PA—2026-07-17 00:00:00
FOX TAPPING INC.
COLUMBIA, PA—2026-07-17 00:00:00
COLUMBIA WATER CO
WILKES BARRE, PA—2026-07-17 00:00:00
NEW ENTERPRISE STONE & LIME CO., INC.
PHILADELPHIA, PA—2026-07-16 00:00:00
MUKHLEEN GERNAROS PIZZA LLC DBA GENARO'S PIZZERIA AND STEAKS
PHILADELPHIA, PA—2026-07-16 00:00:00
CENTER CITY CONSTRUCTION AND DEVELOPMENT, LLC
Source