MEDFORD, NJ —
OSHA Inspection: L.H.J. CONSTRUCTION LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of L.H.J. CONSTRUCTION LLC in 18 ANDOVER DRIVE, MEDFORD, NJ 08055 (NAICS 238140). OSHA activity number 334431731.
Where did this inspection happen?
- Establishment
- L.H.J. CONSTRUCTION LLC
- Site address
- 18 ANDOVER DRIVE
- City
- MEDFORD
- State
- NJ
- ZIP
- 08055
- Mailing
- 4139 ROUTE 563, CHATSWORTH, NJ 08019
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 1
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.451 E06 IV
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $960.00 Reduced
General-duty citation text
29 CFR 1926.451(e)(6)(vi): Integrated prefabricated frame scaffold access frames exceeded the maximum spacing between rungs of 16 3/4 inches (43 cm). a) Jobsite, 18 andover Drive, Medford NJ 08055, Front of the residence: An employee of LHJ Construction LLC. was working on a prefabricated frame tubular welded scaffold and using the end frames to access the different levels of the scaffold, the spacing between the rungs measures approximately 19 inches, observed on or about 04/24/2012.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1926.451 G04 I
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $960.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews: a) Jobsite, 18 Andover Drive, Medford NJ 08055, Front of house: An employee LHJConstruction was working on the second buck up, without the use of fall protection, observed on or about 04/24/2012. ABATEMENT NOTE: Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews. A standard guardrail system includes a top rail, a midrail, and toe boards. The height of the top rail for scaffolds must be between 38 inches (0.97 m) and 45 inches (1.2 m). When the cross point of cross bracing is used as a top rail, it must be between 38 inches (0.97 m) and 48 inches (1.3 m) above the work platform. Midrails must be installed approximately halfway between the top rail and the platform surface. When a cross point of cross bracing is used as a midrail, it must be between 20 inches (0.5 m) and 30 inches (0.8 m) above the work platform.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
More inspections in this industry (NAICS 238140)
RENO, NV—2026-07-16 00:00:00
DC MASONRY
WINNETKA, IL—2026-07-15 00:00:00
CHICAGO STUCCO CO.
WINNETKA, IL—2026-07-15 00:00:00
CHICAGO STUCCO CO.
LODI, NJ—2026-07-15 00:00:00
J & O MASONRY CONTRACTORS
DORAVILLE, GA—2026-07-14 00:00:00
SUDLOW CONCRETE, INC.
More inspections in NJ
EAST ORANGE, NJ—2026-07-17 00:00:00
EAST ORANGE COMMUNITY CHARTER SCHOOL
EAST ORANGE, NJ—2026-07-17 00:00:00
EAST ORANGE COMMUNITY CHARTER SCHOOL
EAST ORANGE, NJ—2026-07-17 00:00:00
EAST ORANGE COMMUNITY CHARTER SCHOOL
MOUNTAIN LAKES, NJ—2026-07-17 00:00:00
JOHN CARUSO BUILDERS LLC
PENNINGTON, NJ—2026-07-16 00:00:00
BOROUGH OF PENNINGTON DEPARTMENT OF PUBLIC WORKS
Source