OSHA Inspection: PREFERRED MASONRY RESTORATION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PREFERRED MASONRY RESTORATION, INC. in 100 SOUTH 7TH STREET, READING, PA 19602 (NAICS 238140). OSHA activity number 334614732.

Watch Preferred Masonry Restoration, INC. — free Get an email when a new federal OSHA severe-injury report for Preferred Masonry Restoration, INC. is published. One employer, no account, unsubscribe in one click.
Site address
100 SOUTH 7TH STREET
City
READING
State
PA
ZIP
19602
Mailing
201 KINTNER HILL ROAD, UPPER BLACK EDDY, PA 18972
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
2
Ownership type
A

3 citations on file for this inspection.

1926.451 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds were not fully planked or decked between the front uprights and the guardrail supports:    (a) Construction Site, Station Interior - On or about June 8, 2012 an employee working on a mobile supported scaffold was drilling into the exterior wall and the working level was not fully decked.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1926.451 G01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level was not protected from falling to that lower level by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section:    (a) Construction Site, Station Interior - On or about June 8, 2012 an employee drilling into an exterior wall from a mobile supported scaffold was  not protected from falling approximately 13 feet to grade.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1926.452 W02

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.452(w)(2): Scaffold casters and wheels were not locked with positive wheel and/or wheel and swivel locks, or equivalent means, to prevent movement of the scaffold while the scaffold is used in a stationary manner.    (a) Construction Site, Station Interior - On or about June 8, 2012 an employee was working on a mobile supported scaffold and the scaffold wheels were not locked in place.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334614732.