WASHINGTON, MO —
OSHA Inspection: SHURE MANUFACTURING CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SHURE MANUFACTURING CORPORATION in 1901 WEST MAIN STREET, WASHINGTON, MO 63090 (NAICS 337214). OSHA activity number 334705605.
Where did this inspection happen?
- Establishment
- SHURE MANUFACTURING CORPORATION
- Site address
- 1901 WEST MAIN STREET
- City
- WASHINGTON
- State
- MO
- ZIP
- 63090
- Mailing
- 1901 WEST MAIN STREET, WASHINGTON, MO 63090
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337214
- Employees
- 52
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C04 II
- Issued
- Abate by
- Penalty
- Initial $1785.00 · Current $1250.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section: a. Although a general lockout program was written (but not updated), there were no specific procedures, as required by 1910.147(c)(4)(ii)(A) through (D), including identification of types and magnitude of energy sources, how the machine is to be powered down and the specific location as to where a lock is to be placed, specifically how the machine is to be tested to ensure it is locked out, and any other specific procedures for the machine identified. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $1249.5
- — Z (S) $1785
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a. An annual inspection (audit) of the lockout program was not done (the general lockout program did identify the need for an annual inspection). Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $1785.00 · Current $1250.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. The unused portion of a band saw was not guarded. b. The light curtain, on a Cincinnati press brake, was not always tested according to the manufacturer's requirements before each day's use. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $1249.5
- — Z (S) $1785
1910.217 C02 I A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.217(c)(2)(i)(a): Point of operation guard(s) on mechanical power press(es) did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guard(s): a. Openings to the point of operation existed on the Bliss punch press, including openings through the front and over the top of the expanded metal barrier guard. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B01 IV
- Issued
- Penalty
- Initial $1517.00 · Current $1062.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(1)(iv): Electric equipment was not free from recognized hazards that were likely to cause serious physical harm to employees, such as damaged electrical insulation: a. In the layout department, a power cord was damaged to the table lift, including outer insulation deterioration and damage at the plug.
Recent events (2)
- — I (S) $1062.08
- — Z (S) $1517.25
More inspections at SHURE MANUFACTURING CORPORATION
WASHINGTON, MO—2023-10-17 00:00:00
SHURE MANUFACTURING CORPORATION
WASHINGTON, MO—2014-07-09 00:00:00
SHURE MANUFACTURING CORPORATION
View SHURE MANUFACTURING CORPORATION's full OSHA safety record →
More inspections in this industry (NAICS 337214)
FOUNTAIN, MN—2026-07-09
111559 - VALLEY DESIGN ENTERPRISES INC
MAHWAH, NJ—2026-05-18
DIMENSIONAL WORLDWIDE, INC.
LIVERPOOL, NY—2026-04-09
ROBERTS OFFICE FURNITURE CONCEPTS INC
LAKE FOREST, IL—2026-03-12
THE UNITED GROUP, INC. DBA INDUSTRIAL SEATS & ERGONOMIC OFFICE CHAIRS CO. DIVISION OF UNITED GROUP, INC.
KENTWOOD, MI—2026-03-10
STEELCASE INC
More inspections in MO
KANSAS CITY, MO—2026-07-09
NIAGARA BOTTLING
MONETT, MO—2026-07-09
MONETT METALS INC.
PARKVILLE, MO—2026-07-08
SKY-TECH ROOFING, LLC.
SPRINGFIELD, MO—2026-07-07
D & C CONSTRUCTION, LLC.
JOPLIN, MO—2026-07-07
SERVICE RECYCLING - NORTH PLANT
Source