OSHA Inspection: P & M SEWER AND WATER, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of P & M SEWER AND WATER, INC. in 1955 W. JEFFERSON, NAPERVILLE, IL 60540 (NAICS 237110). OSHA activity number 334787983.

Watch P & M Sewer AND Water, INC. — free Get an email when a new federal OSHA severe-injury report for P & M Sewer AND Water, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1955 W. JEFFERSON
City
NAPERVILLE
State
IL
ZIP
60540
Mailing
29W755 PETERSON ROAD, MAPLE PARK, IL 60151
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
5
Ownership type
A

3 citations on file for this inspection.

1926.651 C02

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $600.00 Reduced
29 CFR 1926.651(c)(2): Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.    a.  On or about June 19, 2012, at the above addressed jobsite, an employee installing a sewer pipe in an excavation approximately six (6) feet six (6) inches in depth did not have a safe means of egress.    Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1926.651 J02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.651(j)(2): Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations.  Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.    a.  On or about June 19, 2012, at the above addressed jobsite, an employee installing a sewer line in an excavation was not protected from materials falling into the excavation, in that the spoil pile was less than two (2) feet from the edge of the excavation.    Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.652 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1926.652(a)(1):  Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section:    a. On or about June 19, 2012, at the above addressed jobsite, an employee was installing a sewer line in an excavation measured at approximately six (6) feet six (6) inches in depth.  The excavation was not provided with cave in protection, thereby exposing the employee to cave in hazards.    Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

View P & M SEWER AND WATER, INC.'s full OSHA safety record →